OT01-PCR-LA/2
Single-phase Parallel Operation 5-7
3.
Press the F1 key. This starts zero calibration and the following appears
on the display unit:
When zero calibration ends several tens of seconds later, the following appears:
4.
Press the ESC key to exit the zero calibration mode.
The calibrated values will be stored in the PCR-LA power supply memory;
however, conduct re-calibration in accordance with changes in ambient tem-
perature.
5.4.2
Messages Available When Using the RS-232C or GPIB
Interface
Be sure to also read through the PCR-LA AC Power Supply Operation Manual and
the IB03-PCR-LA Operation Manual (when the GPIB Interface is used).
Use the CALPARA message to conduct zero calibration.
No other messages will be accepted until completion of zero calibration, i.e., for
several tens of seconds. The calibrated values will be stored in the PCR-LA power
supply memory. However, conduct re-calibration in accordance with changes in
ambient temperature.
U n d e r
A d j u s t m e n t
I 0 C A L
F1
F2
F3
F4
F5
F i n i s h e d
I 0 C A L
F1
F2
F3
F4
F5