OT01-PCR-LA/2
Installation and Preparation for Use 2-9
2.5.1
Input Power of PCR-LA Power Supplies (Two Units)
• The PCR2000LA, PCR4000LA, and PCR6000LA are permanently
installed AC power supplies. Be sure to connect these power supplies to
the switchboard.
• There is a possibility of electric shock, which could result in injury or death.
To prevent electric shock, turn OFF the switch on the switchboard (to cut
off the power feed from the switchboard) and then connect the input power
cables.
• Connection of the input power cables to the switchboard must be carried
out by a quali
fi
ed personnel.
• Install the input power cable such that the distance between the PCR-LA
power supply and the switch on the switchboard is within 3 m. This proce-
dure facilitates operation of the switch on the switchboard in the event of
emergency.
If the distance to the switch on the switchboard is to be 3 m or more, install
the input power cables with a separate switch provided within 3 m from the
Output Terminal. For such a switch, employ one of two poles that allows
both the L and N poles to be simultaneously disconnected.
Be sure to match the polarity of the input terminals with that of the switchboard (L,
N, and (GND)), and connect the cables securely. If the polarity (L, N, and
) of
the switchboard is unknown, always have it inspected by a quali
fi
ed personnel or
chief electrical technician.
If the input power cables provided cannot be used due to conditions at the installa-
tion site or for any other reason, please consult with a quali
fi
ed personnel or chief
electrical technician, and select the wire size (nominal conductor cross section) of
the cable to be used in accordance with the indoor wiring regulations.
Connecting the input power cables
1.
Remove the terminal-box cover from the rear of an AC power supply,
and connect the provided input power cable(s) to the INPUT terminal
board as shown in Fig. 2-6.
2.
Turn off the switch on the switchboard.
3.
Connect the input power cable(s) to the switchboard.
The switchboard ends of the input power cable(s) provided do not have termi-
nals. For termination, attach a crimp terminal to each wire (cable) that meets
the terminal screws of the switchboard to be connected, then securely connect
the wires (cables) to the terminal screws (connection must be carried out by a
quali
fi
ed personnel).
4.
Set the INPUT VOLTAGE SELECTOR to 170 V AC-250 V AC.
This system is designed especially for 200-V AC input. This step is not neces-
sary for the PCR6000LA, as it is a power supply designed exclusively for 200-
V AC input.
WARNING
Содержание OT01-PCR12000LA/2
Страница 10: ...VIII Contents OT01 PCR LA 2 ...
Страница 16: ...1 6 General OT01 PCR LA 2 ...
Страница 44: ...2 28 Installation and Preparation for Use OT01 PCR LA 2 ...
Страница 56: ...4 8 Part Names and Functions OT01 PCR LA 2 ...
Страница 64: ...5 8 Single phase Parallel Operation OT01 PCR LA 2 ...
Страница 82: ...6 18 Single phase Three wire Operation OT01 PCR LA 2 ...
Страница 94: ...1 2 Index OT01 PCR LA 2 ...
Страница 95: ......
Страница 96: ...OUTPUT EXPANSION KIT OT01 PCR LA 2 OPERATION MANUAL ...