LIN-JF
63
Appendix B
Connecting the PCR-LE and PCR-LE2
This section describes how to use the output terminal of the PCR-LE and PCR-LE2 AC power
supplies. The following description is for connecting the AC power supplies to the LIN-JF. For
other details, see the PCR-LE or PCR-LE2 manual.
WARNING
Risk of electric shock.
• To prevent electric shock, be sure to attach the transparent cover on the rear panel
of the AC power supplies. High voltage will be applied to the terminals.
• Before you connect cables to the AC power supplies’ OUTPUT terminal blocks, be
sure to turn the POWER switch off, and then shut off the power supply from the
switchboard.
• Be sure to ground the AC power supplies to prevent electric shock.
• Never connect the INPUT terminal block of the LIN-JF to the AC line. The internal
circuit of the LIN-JF is not designed to be connected to the AC line.
• Fasten the terminal screws securely. Loose screws are dangerous because the
cables may come loose or the connection may heat up.