98
KHA3000
61000-3-2
Power and Class Options
No.
Menu item
Description
Default
1
Definition of Power
Specify the power value of the EUT. Select
“
Measured
”
or
“
Specified.
”
Measured
2
Specified Power (W)
When “Specified” was selected in the F1 menu, enter the power value
of the EUT. The input range is 0 W to 135,000 W.
Enter the value with the numeric keypad and press the ENTER key, or
use the large knob to increase or decrease the value.
100 W
3
Return
Terminates the power specification.
–
4
PF & Fund Current
(Class C)
Specify the power factor and fundamental current of the EUT. Select
“
Measured
”
or
“
Specified.
”
Measured
5
Specified PF
(Class C)
When
“Specified” was selected in the F1 menu, enter the power factor
value of the EUT. The input range is 0.00 to 1.00.
Enter the value with the numeric keypad and press the ENTER key, or
use the large knob to increase or decrease the value.
1.00
6
Specified Fund Curr (A)
(Class C)
When
“Specified” was selected in the F1 menu, enter the fundamental
current value of the EUT. The input range is 0.0 A to 75.0 A.
Enter the value with the numeric keypad and press the ENTER key, or
use the large knob to increase or decrease the value.
20.0 A
F1
Definition of Power
Sub Menu
F1
Definition of Power
Measured
Specified
F2
Specified Power (W)
(Input numeric value)
F6
Return
F2
Class Options
Sub Menu
F6
F1
PF & Fund Current
Measured
Specified
F2
Specified PF
(Input numeric value)
F3 Specified Fund Curr (A)
(Input numeric value)
F4
Limit Values
Normal
Class A
Class D
3rd/5th/Current Wave
THD Limit
F6
Return
F1
600 W Air Conditioner
No
Yes
F6
Return
→
→
Class C
Class A
1
3
2
4
5
7
6
8
8
9
10
Menu 3/4
Prev/Next
Page 3/4
(IEC Standard)
(JIS Standard)
(JIS Standard)
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......