Appx
KHA3000
373
C
Error List
Command error list
An error in the [-199, -100] range indicates that an IEEE 488.2 syntax error was detected by
the syntax parser of the measuring instrument. If an error in this class occurs, the command
error bit (bit 5) of the event status register is set.
Error code
Explanation of error message
-100
Command error
Generic syntax error
-101
Invalid character
A syntactic element contains a character which is invalid.
-102
Syntax error
An unrecognized command or data type was encountered.
-103
Invalid separator
The parser was expecting a separator and encountered an illegal character.
-104
Data type error
The parser recognized a data element different than one allowed.
-105
GET not allowed
A Group Execute Trigger was received within a program message.
-108
Parameter not allowed
More parameters were received than expected for the header.
-109
Missing parameter
Fewer parameters were received than required for the header.
-110
Command header error
An error was detected in the header.
-120
Numeric data error
Generated when parsing a data element which appears to be numeric, including
the nondecimal numeric types.
-130
Suffix error
Generated when parsing a suffix.
-131
Invalid suffix
The suffix does not follow the syntax, or the suffix is inappropriate for this product.
-134
Suffix too long
The suffix contained more than twelve characters.
-138
Suffix not allowed
A suffix was encountered after a numeric element which does not allow suffixes.
-140
Character data error
Generated when parsing a character data element.
-141
Invalid character data
Either the character data element contains an invalid character, or the element is
not valid.
-144
Character data too Long
The character data element contains more than twelve characters.
-148
Character data not allowed A legal character data element was encountered where prohibited by this product.
-150
String data error
Generated when parsing a string data element.
-160
Block data error
Generated when parsing a block data element.
-170
Expression error
Generated when parsing an expression data element.
-180
Macro error
Generated when defining a macro or executing a macro.
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......