334
KHA3000
System Setting
Buzzer
SYST:BEEP:VOL
Sets the buzzer volume.
Command
SYSTem:BEEPer:VOLume {<numeric>|MIN|MAX}
SYSTem:BEEPer:VOLume?
Parameter Value:
0 to 8
Unit:
None
Response
Returns the buzzer volume in the <NR3> format.
Setting the Date and Time
SYST:DATE
Sets the date.
Command
SYSTem:DATE <YEAR_NR1>,<MONTH_NR1>,<DAY_NR1>
SYSTem:DATE?
Parameter <YEAR_NR1> Year
Value:
2000 to 2099
<MONTH_NR1> Month
Value:
1 to 12
<DAY_NR1> Day
Value:
1 to 31
Response
Returns year, month and day in this order in the <NR1>, <NR1>, <NR1> format.
SYST:TIME
Sets the time.
Command
SYSTem:TIME <HOUR_NR1>,<MIN_NR1>,<SEC_NR1>
SYSTem:TIME?
Parameter <HOUR_NR1> Hour
Value:
0 to 23
<MIN_NR1> Minute, <SEC_NR1> Second
Value:
0 to 59
Response
Returns hour, minute and second in this order in the <NR1>, <NR1>, <NR1> format.
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......