322
KHA3000
Test Execution (Trigger Function)
Sequence 3 (TEST)
INIT:SEQ3
INIT:NAME TEST
Starts testing when IEC 61000-3-3 (ManualSW) is selected in the limit value standard for the
voltage fluctuation measurement mode (VFLuctuation:STANdard:LIMitation).
Command
INITiate[:IMMediate]:SEQuence3
INITiate[:IMMediate]:NAME {TEST}
Parameter Value:
TEST
TRIG:SEQ3
TRIG:TEST
Executes a software trigger during test operation.
Command
TRIGger:SEQuence3[:IMMediate][<character>]
TRIGger:TEST[:IMMediate][<character>]
Parameter Value:
NEXT
(default)
RETRy
TRIG:SEQ3:SOUR
TRIG:TEST:SOUR
Each sets the conditions for actually starting measurement for test operation after reception
of the INIT:SEQ3 command.
When IEC 61000-3-3 (ManualSW) is selected in the limit value standard for the voltage
fluctuation measurement mode (VFLuctuation:STANDard:LIMitation), the second and
subsequent tests always wait for a device trigger. To start the second or a subsequent test,
use a software trigger (*TRG, IEEE 488.1 GET) regardless of the setting of
TRIG:SEQ3:SOUR (TRIG:TEST:SOUR). When the last measurement cycle is completed, it
will not wait for a device trigger.
Command
TRIGger:SEQuence3:SOURce {BUS|IMMediate}
TRIGger:SEQuence3:SOURce?
TRIGger:TEST:SOURce {BUS|IMMediate}
TRIGger:TEST:SOURce?
Parameter Value:
BUS
Start measurement after waiting for a software trigger
(*TRG, IEEE488.1 GET (Group ExecuteTrigger)).
IMMediate
Start measurement immediately (default)
Response
Returns the current setting of the trigger source in the <character> format.
** RST
RST
** RST
RST
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......