KHA3000
Harmonic Measurement Mode (General)
HARM:NOM:VOLT
Sets the nominal voltage. Set the nominal voltage according to the rating of the EUT.
Executing this command simultaneously sets VFL:NOMinal:VOLTage at the same value.
Command
HARMonics:NOMinal:VOLTage <NRf>
HARMonics:NOMinal:VOLTage?
Parameter Value:
100, 120, 200 or 100 to 300 (The default is 230)
Unit:
V
Response
Returns the nominal voltage value in the <NR3> format.
Setting the Margin
HARM:MARG
Sets the margin for the limit value. Set a relative value of the reference limit value (100). For
instance, specify 80 to set the margin to 80 % of the reference limit value.
Command
HARMonics:MARGin {<numeric>|MIN|MAX}
HARMonics:MARGin?
Parameter Value:
10 to 100 (The default is 100.)
Unit:
PCT
Response
Returns the margin in the <NR3> format.
Setting the Measurement Time
HARM:MTIM
Sets the measurement time.
Command
HARMonics:MTIMe {<numeric>|MIN|MAX}
HARMonics:MTIMe?
Parameter Value:
1 to 9600 (The default is 150.)
Unit:
S
Response
Returns the measurement time in the <NR3> format.
Comment Input
HARM:TEXT:COMM
Specifies comment items and sets comment texts. The ten types of comment items listed
below can be specified. The character string for each comment item is subjected to character
code encoding (normally Shift-JIS) that is set by the
“
SYST:CONFigure:TEXT:Encoding
”
command and further subjected to base64 encoding. This double encoding ensures a secure
** RST
RST
** RST
RST
** RST
RST
** RST
RST
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......