The SCPI commands are not case-sensitive.
“
VOLT,
”
“
Volt
”
and
“
volt
”
are all regarded as
short forms of VOLTage.
“
VOLTAGE,
”
“
Voltage
”
and
“
voltage
”
are all accepted as long forms.
•
A space must be inserted between the program header part and the parameter part.
•
When two or more parameters are used, join them with a comma (,).
•
Joining commands with a semicolon (;) forms a compound command.
Example:
SYSTem:TIME 12,34,56;HARMonics:NOMinal:FREQuency {50|60}
●
Compound command
The compound command shown above works the same way as when the following two
commands are entered.
Example: Individual commands
HARMonics:NOMinal:FREQuency {50|60}
HARMonics:NOMinal:VOLTage <NRf>
Because the first command
“
HARMonics:NOMinal:FREQuency
”
specifies
“
HARMonics:
NOMinal
”
as the path, the path can be omitted in the second command.
If a node that is not defined as the current path (except FAIL and PASS) is specified, an error
occurs.
Example: Compound command
HARMonics:NOMinal:FREQuency {50|60};VOLTage <NRf>
●
Compound command (with the specified path cleared)
Example:
SENSe:CURRent:RANGe Maximum;:INITiate
This compound command includes two root nodes
“
SENSe
”
and
“
INITiate.
”
When the second or any other subsequent command begins with a colon, the path specified
in the previous command is cleared.
•
A colon (:) must be inserted between program headers.
•
Colons and semicolons can be used together to connect commands in different
subsystems.
•
Up to 128 bytes of characters can be sent on one line.
Special symbols and characters
The special symbols and characters used to create SCPI commands in this manual are
defined as follows.
Symbol and
character
Description
< >
A character string within <> indicates program data.
Do not include the <> symbols in actual programs.
{ }
Characters or numbers delimited by
“
|
”
in { } mean that one of them should be
selected. Do not include the { } symbols in actual programs.
[ ]
A character string within [ ] indicates an optional data.
If it is not sent with a program, the default value is sent. Do not include the [ ]
symbols in actual programs.
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......