6
KHA3000
139
Executing Harm
onic Tests
Estimating the Rsce (61000-3-12)
Estimate the Rsce before preparing a power supply that satisfies the standard requirements
for the impedance in relation to estimated values. Because the AC power supply does not
have an impedance function that satisfies the standard requirements, the customer is
requested to prepare it separately.
Standard Requirements for Impedance
The standard requirements for the impedance depend on the applied limit value.
•
When the limit value of balanced three-phase equipment with specified conditions is
applied, the impedance must be at least 1.6 times the estimated Rsce.
•
When the limit value of balanced three-phase equipment or other equipment is applied,
the impedance must be equal to or greater than the estimated Rsce.
Selecting the Limit Value
1
Press the HA key.
The HA-Test Conditions List display appears.
2
Press the F6 key to select menu page 1/4.
3
Press the F3 key to select Equipment.
4
Press the F6 key to select menu page 3/4.
5
Press the F4 key to select Limit Value.
Select Except Bal’d 3-P for the limit value of equipment other than balanced three-
phase.
Select Balanced 3-P for the limit value of balanced three-phase equipment.
Select Spec Bal’d 3-P for the limit value of balanced three-phase equipment with
specified conditions.
Select Except Bal’d 3-P for the limit value of the single-phase part of hybrid equipment.
Select Bal’d 3-P for the limit value of the three-phase part of hybrid equipment.
6
Set OUTPUT of the AC power supply to OFF.
7
Ensure the impedance of the AC power supply conforms to the standard
requirements.
To satisfy the standard requirements, the impedance or the AC power supply may need
to be replaced.
8
Set OUTPUT of the AC power supply to ON.
WARNING
•
This work has a risk of electric shock. For the AC power supply used for the
measurement circuit, be sure to disconnect the power cord from the outlet, turn off
the switch on the switchboard to which the power cord is connected, and turn off the
POWER switch.
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......