5-36
KHA1000
5.4.2
Checking AC Power Supply and Repeatability
Menu
Use this menu to check the performance of the AC power supply for a test. Check
the voltage, voltage distortion factor, and frequency using the LOAD terminal of
this product. When the connection cable to the EUT is long, standard requirements
may not be satisfied because of an increase in voltage drop and inductance.
Judgment results are displayed as “PASS” or “FAIL.” Depending on the
requirements of the standard, the judgment timing is as shown below.
Table 5-9
AC Power supply check timing
•
To prevent an electric shock, do not touch the SOURCE or LOAD
terminals of this product.
•
Do not touch the OUTPUT terminal of the AC Power Supply.
•
Do not touch the INPUT or OUTPUT terminals of the Line Impedance
Network.
Select View Items
→
Sub Menu
F 1
F 1
F 2
F 2
F 3
F 3
F 4
F 4
F 5
F 5
F 6
F 6
Page
2/2
F4
Check AC
Power Supply
Sub Menu
Standard name
notation
Description
IEC Ed5.0/Ed2.1
IEC Ed5.0/Ed1.0
IEC Ed3.0/Ed2.0
IEC Ed2.2/Ed2.0
IEC Ed3.0/Ed1.0
IEC Ed2.2/Ed1.0
JIS 2005/Ed2.0
*1
JIS 2005/Ed1.0
*1
JIS 2019/Ed2.0
*1
JIS 2019/Ed1.0
*1
*1. When Reference Impedance is set to Unuse.
The judgment is performed on the measured values
during the test.
JIS 2005/Ed2.0
*2
JIS 2005/Ed1.0
*2
JIS 2019/Ed2.0
*2
JIS 2019/Ed1.0
*2
*2. When Reference Impedance is set to Use.
Realtime measurement and judgment is performed
when tests are not being executed.
When you select these standards, you have to perform
judgments with the EUT turned off before you start the
test.
WARNING
F1
Select View
Items
Measured
Values
Recorded
Values
F2
Record
Press this to record the
current measured value. The
recorded value will be
retained until you turn the
power off.
Содержание KHA1000
Страница 1: ...Part No Z1 003 482 I0043901 Oct 2021 Operation Manual Harmonic Flicker Analyzer KHA1000 ...
Страница 8: ...vi KHA1000 ...
Страница 20: ...xviii KHA1000 Rear panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ...
Страница 22: ...xx KHA1000 ...
Страница 23: ...Overview This chapter provides an overview of the product and explains its features 1 ...
Страница 30: ...1 8 KHA1000 ...
Страница 68: ...3 20 KHA1000 ...
Страница 69: ...Basic Operation This chapter explains basic operation methods 4 ...
Страница 156: ...5 54 KHA1000 ...
Страница 183: ...Other Measurements This chapter explains measurements for other than harmonic current and voltage fluctuation tests 7 ...
Страница 193: ...Remote Control This chapter explains how to connect the remote interface and how to control it using SCPI commands 8 ...
Страница 260: ...9 6 KHA1000 ...
Страница 261: ...Specifications This chapter explains the specifications of this product 10 ...
Страница 272: ...I 4 KHA1000 ...
Страница 273: ......