
2
5
.4.12
Operation instructions: Control head 5630xxx010-000
ASi-Bus ES/ABSL
9
12. Position control and position indication
12.1 Lifting valve
The repeat signal message ‘valve opened‘ or ‘valve closed‘ occurs contactless through the magnet field
of the pulse initiator‘s toric magnets at coverage of the Hall sensors on the board.
Valve Position Indicator
➣
ELECTRICAL - through the DUO - LED on the board
• valve ’’OPEN’’ = Signal DUO-LED GREEN
• valve ’’CLOSED’’ = Signal DUO-LED RED
➣
MECHANICAL - Lifting position of spindle
• valve ’’OPEN’’ = Valve position indicator - green
• valve ’’CLOSED’’ = Valve position indicator - red
NOTE
The installation position of the pulse generator is characterized by a marking in the spindle.
The distances of the measures " A" and " B" are valve-specifically and adjusted by the factory. These
must not be adjusted.
Puls generator
Fig. 2
Содержание 5630 201 010-000
Страница 1: ......