42
SEG
Operating Instructions
5 Mounting and dismounting
5.5.2
Detaching the electrical connections
1. Remove the screwed cable gland nut (
11
).
2. Remove the cable in the pull-rope emergency stop
switch from fastening clamp (
14
) and remove the
cable tie if applicable
.
Note!
To mount a new pull-rope emergency stop
switch or a repaired pull-rope emergency stop
switch, we recommend that the connections be
labeled with the connection designations for the
pull-rope emergency stop switch before the
connection cables are disconnected.
3. Disconnect the connection cable between the safety
and control circuits and the switching elements (
5
,
6
)
and if applicable, disconnect the connection cable
for the signal lamp (
12
) as described in
„Electrical connection“, page 24
.
4. Disconnect the protective conductor on the protec-
tive conductor connection M4 (
8
).
5. Remove the cable from screwed cable gland (
11
).
Fig. 5-6:
Electrical connections
X1
X2
13
14
33
34
53
54
21
22
41
42
61
62
X1
X2
1
2
6
(N/O contact,
control circuit)
5
(N/C contact,
safety circuit)
12
Pull rope side
14
12
8