4 Technical data
4
Technical data
4.1
General technical data
Designation
Pull-rope emergency stop switch
Version
Emergency stop switch with actuation in both directions
Area of application
Control circuit, stop category 1 in accordance with DIN EN ISO 13850
Requirements and standards that have been met
DIN EN ISO 13850, DIN EN 60947-5-5, DIN EN 60947-5-1, DIN EN 60947-1, DIN EN 620, BGI 710
Suitable for
Control units and systems in accordance with EN 60204
Electrical data
Switching system
Cam switch as N/C and N/O contacts with double break
Positive opening contacts in accordance with DIN EN 60947-5-1, appendix K
Min. equipment: 1 N/C and 1 N/O contact
Max. equipment: 3 N/C and 3 N/O contacts
Usage category
AC-15: AC 230 V / 6 A
DC-13: DC 110 V / 1.1 A
Rated insulation voltage U
i
400 V
Design surge voltage strength U
imp
2,5 kV, Overvoltage category II, 2000 m above sea level, contamination level 3
Conventional thermal current I
th
16 A
Conditional short circuit current
1000 A
Short circuit protection
16 A (time-delay)