Z45FK, Z46FK, Z47FK, Z60FK

Product Description

L

Page 3 / 8

2.90-20.060-01-EN | 2022-10-05

Item

Technical data

Accessories (not included in delivery)

Z45FK

Coupling relay with one changeover switch

Z46FK

Coupling relay with two changeover switches

Z47FK

Coupling relay with one changeover switch und a manual switch at field level

Z60FK

Coupling relay with one changeover switch und a manual switch at field level with a 
potential-free feedback contact

Nominal voltage

Z45FK/Z47FK/Z60FK  AC/DC 24 V ±10%, 13 mA
Z46FK 

AC/DC 24 V ±10%, 20 mA

Output contact

Z45FK/Z47FK/Z60FK  1 changeover switch, max. AC 250 V, 6 A, 

1500 VA

Z46FK

2 changeover switches, each with max. AC 
230 V, 0.25 A, 60 VA

Feedback contact

Z60FK

Max. AC/DC 24 V; 50 mA

Electrical service life

Z45FK, Z47FK, Z60FK 200,000 switching cycles
Z46FK

2,000,000 switching cycles

Display

LED operating display

Manual switch

Z45FK/Z46FK

None

Z47FK

Manual switch at field level

Z60FK

Manual switch at field level with a poten-
tial-free feedback contact

Connection

Solid wire

0.08 .. 2.5 mm²

Litz wire without
conductor end sleeve

0.08 .. 2.5 mm²

Litz wire with conduc-
tor end sleeve

0.5 .. 1.5 mm²

Overvoltage category

III

Rated impulse voltage

4000 V

Level of contamination

2

Automatic action

Type 1

Degree of protection

Housing

IP20

Insulation in accordance with 
VDE 0110

Z45FK, Z47FK, Z60FK Rated voltage 250 V

Z46FK

Rated voltage 230 V

Ambient temperature

-20 .. +55 °C

Weight

43 g

Mounting

Control panel installation on standard top-hat rail TH 35-7.5; can be 
snapped open without there having to be free space to the left/right; 
installation position can be chosen freely

Z43

Connecting bridge for connecting up to 10 analog encoders or coupling relays using termi-
nal slots for the “A1” and “A2” connections (power). Maximum 2 A total current. 

Содержание Z45FK

Страница 1: ...are fitted with spring terminals which make it possible to connect wires quickly and easily It is not necessary to use a tool to connect solid wires and litz wires with conductor end sleeves an ordina...

Страница 2: ...mmissioning work on the devices may only be carried out by qualified technicians Qualified technicians are persons who are familiar with the described product and who can assess given tasks and recogn...

Страница 3: ...es Z46FK 2 000 000 switching cycles Display LED operating display Manual switch Z45FK Z46FK None Z47FK Manual switch at field level Z60FK Manual switch at field level with a poten tial free feedback c...

Страница 4: ...05 Dimensions Connection ZxxFK Z43 250 V AC 6 A 1500 VA 11 A1 14 12 GN A2 Z45FK 14 24 12 22 11 A1 21 230 VAC 0 25 A 60 VA GN A2 Z46FK A1 A3 0 ON A3 AUTO OFF 11 A1 12 14 250 V AC 6 A 1500 VA GN A2 Z47F...

Страница 5: ...c installation can cause death due to electric shock Mounting removal may only be carried out when power is switched off Comply with VDE guidelines and local wiring regulations when mounting removing...

Страница 6: ...any further and it clicks into place in the spring terminal In the case of litz wires without conductor end sleeves the spring terminal must be opened using a slotted screwdriver Insert the screwdrive...

Страница 7: ...oper place to make the cut Then insert the connecting bridge Z43 from the top or from the bottom into the contact slot and press it down WARNING Contact with live components of the building s electric...

Страница 8: ...are switched at the output terminals In secondary earthed systems PELV this prevents any unwanted connection to ground or the reference potential and prevents an active signal from being generated at...

Отзывы: