Kieback&Peter DDC111 Скачать руководство пользователя страница 2

A

Page 2 / 8

Product Description

DDC111, DDC111-2

Datasheet 1.10-51.111-01-EN

Issue 2012-05-09

Important Information Regarding Product Safety

Safety Instructions

This data sheet contains information on installing and commissioning the product "DDC111, 
DDC111-2". Each person who carries out work on this product must have read and understood this 
data sheet. If you have any questions that are not resolved by this data sheet, you can obtain further 
information from the supplier or manufacturer.
If the product is not used in accordance with this data sheet, the protection provided will be impaired.
Applicable regulations must be observed when installing and using the device.  Within the EU, these 
include regulations regarding occupational safety and accident prevention as well as those from the 
VDE (Association for Electrical, Electronic & Information Technologies). If the device is used in other 
countries, it is the responsibility of the system installer or operator to comply with local regulations.
Mounting, installation and commissioning work on the devices may only be carried out by qualified 
technicians. Qualified technicians are persons who are familiar with the described product and who 
can assess given tasks and recognize possible dangers due to technical training, knowledge and 
experience as well as knowledge of the appropriate regulations.

Legend

WARNING

Indicates a hazard of medium risk which can result in death or severe bodily injury if it is not avoided.

CAUTION

Indicates a hazard of low risk which can result in minor or medium bodily injury if it is not avoided.

!

NOTICE

Indicates a hazard of medium risk which can result in material damage or malfunctions if it is not 
avoided.

NOTE

Indicates additional information that can simplify the work with the product for you.

Notes on Disposal

For disposal, the product is considered waste from electrical and electronic equipment (electronic 
waste) and must not be disposed of as household waste. Special treatment for specific components 
may be legally binding or ecologically sensible. The local and currently applicable legislation must be 
observed.

Содержание DDC111

Страница 1: ...oom control modulel Application The room control modules are used together with the technolon RCNxxx L or FBR110 L room controllers A room control module can be connected to each technolon room contro...

Страница 2: ...perator to comply with local regulations Mounting installation and commissioning work on the devices may only be carried out by qualified technicians Qualified technicians are persons who are familiar...

Страница 3: ...t in steps of 0 1 K Symbol display to indicate operating mode Fan levels DDC111 2 operating buttons button Switches to temperature mode for setting the room temperature setpoint button Switches to fan...

Страница 4: ...ge 4 8 Product Description DDC111 DDC111 2 Datasheet 1 10 51 111 01 EN Issue 2012 05 09 Dimensions Connection 82 5 28 3 82 5 RJ9 DDC111 2 DDC111 RJ9 15 cm 0V 5V Tx Rx sw rt gr gl Z178 2 RJ9 10 m Z178...

Страница 5: ...power is switched off The room control module can be mounted on the wall or onto a flush mounted box Choose an installation location that is subject to the air flow of the room to ensure that the room...

Страница 6: ...odule automatically switches back to the standard display after 5 seconds The new room temperature setpoint is saved Switching fan levels on or off Fan levels are automatically switched on and off by...

Страница 7: ...the room control module automatically switches back to the standard display after 5 seconds The new room temperature setpoint is saved Switching on day or stand by mode The central program automatica...

Страница 8: ...ry fan levels can also be switched manually by the user Manual control Press the button The room control module switches to the manually adjustable fan mode The function symbol is displayed and the cu...