manualshive.com logo in svg
background image

AC Powered with Battery Backup

Carbon Monoxide 

Alarm

User’s Guide

with Digital Display, Peak Level Memory, and Battery Backup

Model: KN-COPD-3-UK

Please have the following information

ready when calling:

Alarm Model number (located on front of alarm):

Alarm Assembly number (located on back of alarm):

Date of Manufacture (located on the back of the  alarm):

Date of Purchase:

Where Purchased:

For questions concerning your  Alarm, please 

call Kidde Safety Europe on 01753 685148 

Attention:

Please take a few minutes to thoroughly read this manual, which should be saved for future

reference and passed on to any subsequent owner. If you have any questions about the operation or instal-

lation of your alarm, please call Kidde Safety Europe on 01753 685148 

KM 98848

EN50291:2001

Includes a

9 Volt Battery

820-1196 REV. A
2520-7203-00

2520-7203-00.qxd  2006.4.7  3:50 PM  Page 1

Содержание KN-COPD-3-UK

Страница 1: ...back of the alarm Date of Purchase Where Purchased For questions concerning your Alarm please call Kidde Safety Europe on 01753 685148 Attention Please take a few minutes to thoroughly read this manu...

Страница 2: ...Home safety tips Determine if anyone in the household is at high risk for CO poisoning The Effects of Carbon Monoxide Exposure Understand the effects of carbon monoxide exposure What to Do When the U...

Страница 3: ...PRODUCT IS INTENDED FOR USE IN ORDINARY INDOOR RESIDENTIAL AREAS IT IS NOT DESIGNED TO MEASURE COMPLIANCE WITH COMMERCIAL AND INDUSTRIAL STAN DARDS THE INSTALLATION OF THIS DEVICE SHOULD NOT BE USED...

Страница 4: ...larm for complete instructions about how to configure your alarm for installation Step 4 Install the alarm Plug the alarm into a standard un switched 230 volt AC electrical outlet in one of the alarm...

Страница 5: ...l is burned When oxygen is limited during combustion more CO is produced Serious problems can develop when combustion by products are not properly vented outside the house That s why it s so important...

Страница 6: ...y Peak Level Button By pressing this button you can see the peak CO level recorded by the alarm since it was last cleared or unplugged This Kidde alarm feature allows you or heating contractor or fire...

Страница 7: ...areas without reaching the alarm Doors or other obstructions may affect the rate at which CO reaches the unit In addi tion fresh air from a vent or open window or any other source may pre vent CO from...

Страница 8: ...rted Within hours of starting a vehicle and backing it out of the garage the level of remaining CO present can activate the alarm and cause a nuisance alarm In the kitchen some gas appliances can emit...

Страница 9: ...ld humid air with extended periods between cycles 2 Negative pressure differential resulting from the use of exhaust fans 3 Simultaneous operation of several fuel burning appliances com peting for lim...

Страница 10: ...facing you adapter at top use a small screwdriver or similar tool to pry the back cover up to release it 2 Remove the back cover 3 Next place your thumb on the adapter thumb release and pull the adapt...

Страница 11: ...e digital display The blinking dot indicates that the alarm is operating Within 20 seconds your CO alarm will start monitoring for CO Note The number will probably be zero 0 This is a normal condition...

Страница 12: ...arm You should test the alarm once a week following the directions listed below If at any time you test the alarm and it does not perform as described have it replaced immediately Turn to How to know...

Страница 13: ...on Signal Group 1 Component Failure An intermittent chirping alarm will sound every 30 seconds An Err message will appear on the digital display The yellow LED will light continuously and The unit doe...

Страница 14: ...the sensor Avoid spraying air freshener hair spray paint or other aerosols near the alarm Do not paint the alarm Paint will seal the vents and interfere with proper sensor operation Do not mount the a...

Страница 15: ...e alarm will begin monitoring for CO within a few min utes The Effects of CO Exposure When you breathe carbon monoxide it enters your bloodstream through your lungs and attaches to red blood cells The...

Страница 16: ...home Keep fuel burning appliances their chimneys and vents in good working condi tion Learn the early symptoms of CO exposure If you suspect CO poisoning move outside to fresh air and get emergency h...

Страница 17: ...may be the cause when family members suffer from flu like symptoms that don t disappear but improve when they leave home for extended periods of time Be Aware of the Warning Signs of Carbon Monoxide I...

Страница 18: ...ning than a healthy adult Pregnant women should be aware that their unborn fetus could be harmed by exposure to CO even when the mother suffers no ill effect Any pregnant woman who suspects she may ha...

Страница 19: ...of the CO problem has been identified and corrected The Effects of Carbon Monoxide Exposure 17 The Effects of Carbon Monoxide Exposure 100 200 400 800 1600 3200 6400 12800 PARTS PER MILLION PERCENT OF...

Страница 20: ...xide 1 Operate test reset button 2 Call Transco British Gas 3 Immediately move to fresh air Do a head count to check that all persons are accounted for Do not re enter the premises until British Gas r...

Страница 21: ...ek care from a physician CO poisoning can be determined by a simple blood test called a carboxy haemoglobin test This test measures the amount of CO in the bloodstream For this test to be accurate it...

Страница 22: ...ve provided ventilation by leaving your windows and doors open the CO build up may have dissipated by the time help responds Although your problem may appear to be temporarily solved it s crucial that...

Страница 23: ...onstantly when the alarm malfunctions Battery Backup A 9 volt battery is needed If battery is low or missing while the unit is plugged into a 230V outlet an Lb message will display which will blink al...

Страница 24: ...F atmospheric pressure 10 40 3 relative humidity Reading Tolerance of display reading 0 999 PPM 20 15 ppm Technical Information 22 This Kidde alarm meets the alarm response time requirements as follow...

Страница 25: ...members to the difference between a CO reading and a reading signifying a problem with the alarm itself Display Readings Start up and Normal Operation Readings If at any time the alarm does not perfo...

Страница 26: ...ormal battery only operation unit will show reading only if it senses CO Unit malfunctioning when Battery powered Very low battery unit will not respond to CO Near dead battery or unit malfunction Rep...

Страница 27: ...no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other us...

Страница 28: ...express or implied written or oral including that of merchantability or fitness for any par ticular purpose with respect of the batteries For Warranty Service In many cases the quickest way to exchan...

Страница 29: ...service department on 01753 685148 or contact us at our website at www kiddesafetyeurope co uk Kidde Safety Europe Mathisen Way Colnbrook SL3 0HB UK Copyright Walter Kidde Portable Equipment 2005 All...

Отзывы: