ATTENTION: Please take a few minutes to thoroughly read this
user’s guide which should be saved for future reference and passed
on to any subsequent owner.

Carbon Monoxide Alarm

User’s Guide

KM 98848

EN50291:2001

Models:

KN-COPP-B-LS-UK (900-0230)

and

KN-COB-B-LS-UK (900-0233)

KN-COPP-B-LS-UK
(900-0230)

with Digital Display

KN-COB-B-LS-UK
(900-0233)

• Peak Level Memory

• 3-AA Battery Operation

2522-7206-00(820-1727 A)-R1:Layout 1  2009.8.19  6:51 PM  Page 1

Содержание KN-COB-B-LS

Страница 1: ...future reference and passed on to any subsequent owner Carbon Monoxide Alarm User s Guide KM 98848 EN50291 2001 Models KN COPP B LS UK 900 0230 and KN COB B LS UK 900 0233 KN COPP B LS UK 900 0230 wi...

Страница 2: ...e enter the premises until gas emergency services have arrived the premises has been aired out and your alarm remains in its normal condition 4 After following steps 1 3 if your alarm reactivates with...

Страница 3: ...ymptoms sooner Each year a qualified Gas Safe gas or Hetas solid fuel engineer should inspect and clean your heating system vents chimney and flues Your new Kidde CO alarm has a seven year warranty Pl...

Страница 4: ...device is designed to protect individuals from acute effects of carbon monoxide exposure It may not prevent the chronic effects of carbon monoxide exposure It may not fully safeguard individuals with...

Страница 5: ...hile victims are aware they are not well they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance Also young children and household pets m...

Страница 6: ...inside front cover Low Levels Generally below 50 PPM Kidde recommends you take action to eliminate the source of CO See What to do When the Alarm Sounds inside front cover IMPORTANT Model KN COB B LS...

Страница 7: ...ces or water heaters Obstructions in or unconventional vent pipe designs which can amplify the above situations Extended operation of unvented fuel burning devices range oven fireplace etc Temperature...

Страница 8: ...r CO alarm weekly because it could fail to operate at any time If your CO alarm fails to test properly or if its self diagnostic test reveals a malfunction immediately have the unit replaced This alar...

Страница 9: ...al power up this alarm will beep every 30 seconds to indicate that it is time to replace the alarm Replace the alarm immediately It will not detect CO in this condition To help identify the date to re...

Страница 10: ...KITCHEN BEDROOM BEDROOM BEDROOM LIVING ROOM Recommended Locations Temperature Operating Range 40 F 4 4 C to 100 F 37 8 C Humidity Operating range 10 95 non condensing Audible Alarm 85 dB at 10 3 4 0...

Страница 11: ...de recommends 5 metres to prevent nuisance alarms Do not install near vents flues chimneys or any forced unforced air ventilation openings Do not install near ceiling fans doors windows or areas direc...

Страница 12: ...t installed When replacing the batteries use one of the following approved brands Duracell MN1500 or MX1500 Energizer E91 GoldPeak 15A Golden Power GLR6A These batteries can be purchased where you bou...

Страница 13: ...ll drill a 3 16 hole in the wall and use the plastic anchors provided 3 Hook the CO alarm over the screws and onto the keyholes in the back of the alarm Your CO alarm may also be placed on a tabletop...

Страница 14: ...r Red LED constantly on Constant alarm Very low battery or unit malfunction Replace battery If condition continues unit has malfunctioned Replace immediately Unit will not respond to CO Normal Test Re...

Страница 15: ...s every 30 secs None Normal DC operation with good batteries sensing no CO None Lb flashes alternately with any number Red LED flashes every 30 seconds One quick beep every 30 seconds Batteries need t...

Страница 16: ...s of CO between 1 and 30 PPM can often occur in normal everyday conditions Concentrations of CO below 30 PPM may be an indication of a transient condition that may appear today and never reappear Some...

Страница 17: ...r alarm in good working order you must follow these steps Verify units alarm lights and battery operation by pushing the test reset button once a week Vacuum the alarm cover once a month to remove acc...

Страница 18: ...of substances that at high levels can damage the sensor or cause temporary readings that are not CO readings Ethylene ethanol alcohol iso propanol benzene toluene ethyl acetate hydrogen hydrogen sulf...

Страница 19: ...ility in tort or otherwise The Manufacturer shall have no liability for any personal injury property damage or any special incidental contingent or consequential damage of any kind resulting from gas...