SMOKE ALARM DESCRIPTION
Model KF1
Ionisation 230V AC smoke alarm with 9V
battery back-up and Hush Button
Model KF1R
Ionisation 230V AC smoke alarm with recharge-
able battery backup and Hush Button
Model KF2
Optical 230V AC smoke alarm with 9V
battery back-up with Hush Buttonl
Model KF2R
Optical 230V AC smoke alarm with rechargeable
battery back-up and Hush Button
SMOKE ALARM FEATURES
• Interconnects with up to 23 other models, KF1, KF1R, KF2, KF2R, KF3, KF3R,
4870, 4881, 4973, 4985, 4892, 4899, 1SFW, 1SFWR, 2SFW, 2SFWR, 3SFW and
3SFWR. Unique power connector prevents interconnection with incompatible
smoke alarms or security systems.
• Tamper-resist bracket quickly snaps into place and serves as a safeguard
against tampering.
• Multi-purpose green and red LEDs indicate that the smoke alarm is receiving
AC power, working under normal operation, in alarm, or under Hush Button.
• Loud alarm horn—85 decibels at 3 metres (10 feet)—sounds to alert you of
an emergency.
• Test button checks smoke alarm operation.
• Models KF1, KF1R, KF2 and KF2R feature Hush Button, which, when
activated, quiets unwanted alarms for up to 15 minutes.
• Models KF1 and KF2 will not attach to the mounting bracket if a
battery is not in the battery pocket. These models will also sound a short
beep about once a minute if the battery is weak or improperly connected.
• Models KF1R and KF2R include permanent rechargeable lithium
batteries.
• Operating temperature: 0°C to 40°C
• Operates up to 93% humidity (non-condensing)
IMPORTANT SAFETY INFORMATION
PLEASE READ AND SAVE THESE
INSTRUCTIONS
W
A
R
N
I
N
G
•
DO NOT paint or cover the smoke alarm with tape.
•
This smoke alarm should be out of the reach of children.
•
AC smoke alarms require constant 230V AC, 50Hz power to operate
properly.
Mains-powered smoke alarms WILL NOT work if AC power is not
connected or has failed or been interrupted for any reason. Models KF1 and
KF2 require a working 9-volt battery to operate properly in the event of a
power failure. Models KF1R and KF2R require a minimum of 2 full days
under mains power to reach full backup capacity. DO NOT use any other
kind of battery except as specified in this manual. DO NOT connect this
smoke alarm to any other type of smoke alarm or auxiliary device, except
those listed in this manual.
•
DO NOT remove or disconnect battery or turn off AC power to quiet
unwanted alarms.
This will remove your protection. Open windows or fan the air
around smoke alarm to silence it. KF1, KF1R, KF2 and KF2R smoke alarms
feature a Hush Button which, when activated, will quiet unwanted alarms for up to
15 minutes.
•
The Push-to-Test button accurately tests all smoke alarm functions.
DO NOT use any other test method.
Test smoke alarm weekly to
ensure proper operation.
•
This smoke alarm should be installed only by a qualified
electrician.
•
This smoke alarm is designed to be used inside a single family
household only.
In multi-family buildings, each individual living unit
should have its own smoke alarms. Do not install in non-residential
1
USER’S MANUAL
PLEASE READ AND SAVE
INSTALLER: Please leave this manual with the product.