AC Wire-in Single and/or Multiple Station (up to 24 Devices) Heat Alarm
with 9 Volt Battery Back Up, 135ºF fixed temperature.

Thank you for purchasing this heat alarm.  It is an important part of your family’s
home safety plan.  You can trust this product to provide the highest quality safe-
ty protection.  We know you expect nothing less when the lives of your family
are at stake.  Kidde alarms and accessories CAN ONLY BE interconnected with
other Kidde alarms and accessories as well as specified brands and models of
interconnect compatible alarms.  Connection of Kidde products to a non-speci-
fied manufacturer’s interconnect system, or connection with non-specified
equipment from another manufacturer into an existing Kidde system could result
in nuisance alarming, failure to alarm, or damage to one or all of the devices in
the interconnect system. Refer to the User’s Guide supplied with each Kidde
product for interconnect compatible models, brands, and devices. Refer to the
wiring instructions in section 3 for NFPA initiating device limits

For model: HD135F

820-0917 Rev. B

11/2006

HD135F

For your convenience, write down the following information.  If you call

our Consumer Hotline, these are the first questions you will be asked.

Heat Alarm Model Number
(located on back of alarm):

Date Code (located on back of alarm): The
National Fire Protection Association (NFPA)
and the manufacturer recommend replacing
this alarm ten years from the date code.

Date of Purchase:

Where Purchased:

Heat Alarm User’s Guide

Содержание HD135F

Страница 1: ...non specified equipment from another manufacturer into an existing Kidde system could result in nuisance alarming failure to alarm or damage to one or all of the devices in the interconnect system Re...

Страница 2: ...IONS 2 RECOMMENDED LOCATIONS OF ALARMS 3 LOCATIONS TO AVOID 4 INSTALLATION INSTRUCTIONS 5 OPERATION AND TESTING 6 FALSE ALARMS 7 MAINTENANCE 8 LIMITATIONS OF HEAT ALARMS 9 GOOD SAFETY HABITS 10 NFPA P...

Страница 3: ...ese cases the alarm should be mounted on an inside wall If the alarm cannot be located in the center of the room an off center location can be used on the ceiling When off cen ter mounting an alarm on...

Страница 4: ...d to present stan dards extreme heat or cold can be transferred from the outside to the inside through poorly insulated walls and roof This may create a thermal barrier which can prevent the heat from...

Страница 5: ...ot protected by a ground fault interrupter WARNING This alarm cannot be operated from power derived from a square wave or modified square wave inverter These type of inverters are sometimes used to su...

Страница 6: ...equired by local codes avail able at all electrical supply stores and most hardware stores FIGURE 4 INTERCONNECT WIRING DIAGRAM WIRES ON ALARM HARNESS CONNECTED TO Black Hot Side of AC Line White Neut...

Страница 7: ...s near each mounting hole in the trim ring to help you select the correct mounting holes see figure 5 4 Pull the AC QUICK CONNECTOR through the center hole in the trim ring and mount the ring making s...

Страница 8: ...he bat teries Use long nose pliers to pull the pin out of the hole It is now possible to remove the alarm from the trim ring After installation TEST your alarm by pressing and holding the test button...

Страница 9: ...iginating alarm or alarm being tested will flash rapidly All other units in the interconnect sys tem will sound an alarm but their red LED s will NOT flash rapidly The green LED is located under the o...

Страница 10: ...ss squeeze the locking arms on the sides of the Quick Connector while pulling the connector away from the bottom of the alarm see section 4 figure 6 BATTERY INSTALLATION AND REMOVAL To replace or inst...

Страница 11: ...TO FOLLOW BATTERY INSTALLATION INSTRUCTIONS PRINTED ON THE INSIDE OF THE BATTERY DOOR AND USE ONLY THE BATTERIES SPECIFIED USE OF DIFFERENT BATTERIES MAY HAVE A DETRI MENTAL EFFECT ON THE SMOKE ALARM...

Страница 12: ...E OF THE SPECIFIED TYPE IN GOOD CONDI TION AND INSTALLED PROPERLY AC POWERED ALARMS WILL NOT OPERATE IF AC POWER HAS BEEN CUT OFF SUCH AS BY AN ELECTRICAL FIRE OR AN OPEN FUSE ALARMS MUST BE TESTED RE...

Страница 13: ...o test your plan before an emergency You may not be able to reach your children It is important they know what to do Current studies have shown smoke alarms may not awaken all sleeping individuals and...

Страница 14: ...nity of the sleeping rooms 3 On each level of the dwelling unit including basements Exception In existing one and two family dwelling units approved smoke alarms powered by batteries are permitted Smo...

Страница 15: ...y of but outside of the bed rooms and heat or smoke alarms in the living rooms dining rooms bedrooms kitchens hallways attics furnace rooms closets utility and storage rooms base ments and attached ga...

Страница 16: ...LARM OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF THE HEAT ALARM AND IN NO CASE SHALL KIDDE SAFETY OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATION...

Страница 17: ...consecuencia alarmas molestas fallas de la alarma o da os a uno o todos los dispositivos del sistema interconectado Consulte la Gu a del usuario que se entrega con cada producto Kidde para conocer lo...

Страница 18: ...SERVICIO Y GARANT A No intente reparar esta alarma de calor Consulte las instrucciones en la Secci n 11 para obtener informaci n sobre servicio 1 ESPECIFICACIONES N mero de modelo HD135F CA 120 VCA 60...

Страница 19: ...lg 30 5 cm bajo el cielo raso consulte la Figura 1 Instale las alarmas de calor en cielos rasos con pendiente a dos vertientes o catedral a 3 pies 0 9 m o menos del punto m s alto medido horizontalmen...

Страница 20: ...si observa que las paredes externas y el cielo raso est n calientes o fr os instale la alarma en una pared interna ADVERTENCIA PRUEBE EL FUNCIONAMIENTO DE LA ALARMA DE CALOR DESPU S DE QUE SU VEH CULO...

Страница 21: ...una pieza de metal ni con la caja el ctrica Cuando las alarmas est n interconectadas todas las unidades interconectadas deben activarse desde un circuito nico En una configuraci n de m ltiples estacio...

Страница 22: ...de la alarma 2 Despu s de seleccionar la ubicaci n adecuada para la alarma contra humo como se describe en la Secci n 2 y de conectar los cables de CONEXI N R PIDA DE CA seg n se describe en las INSTR...

Страница 23: ...seguridad contra la manipulaci n indebida para cambiar las bater as Use un alicate de punta larga para sacar el pasador del orificio Ahora puede sacar la alarma del anillo de ajuste Despu s de la inst...

Страница 24: ...defectuosa en cuyo caso debe devolverla para que sea reparada CONSULTE LA SECCI N 12 6 FALSAS ALARMAS Para evitar las falsas alarmas NO LA USE EN LUGARES EN DONDE LA TEMPERATURA AMBIENTE SUPERE LOS 10...

Страница 25: ...S LO LAS BATER AS QUE SE ESPECIFICAN EL USO DE BATER AS DIFERENTES PUEDE TENER UN EFECTO PERJUDICIAL EN LA ALARMA CONTRA HUMO LIMPIEZA DE SU ALARMA LA ALARMA SE DEBE LIMPIAR UNA VEZ AL A O COMO M NIMO...

Страница 26: ...ECTAR ENTRE S Y CON LAS ALARMAS DE CALOR AUNQUE LAS ALARMAS DE CALOR CUANDO SE COMBINAN CON LAS ALARMAS DE HUMO PUEDEN AYUDAR A SALVAR VIDAS AL PROPORCIONAR UNA OPORTUNA ADVERTENCIA DE UN INCENDIO NO...

Страница 27: ...a y dos viviendas unifamiliares 2 Afuera de cada dormitorio y pr ximo a los mismos 3 En cada nivel de la vivienda unifamiliar incluyendo el s tano excepto Se permite el uso de alarmas contra humo acci...

Страница 28: ...E SAFETY O DE CUALQUIER SOCIEDAD DE CONTROL O SUBSIDIARIA QUE SURJA DE LA VENTA DE ESTA ALARMA O SEG N LOS T RMINOS DE ESTA GARANT A LIMITADA EN NING N CASO DEBE EXCEDER EL COSTO DEL REEMPLAZO DE LA A...

Отзывы: