Manual P/N 820-1562 Rev. A 08/2008

ATTENTION: Please take a few minutes to thoroughly read this
user’s guide which should be saved for future reference and
passed on to any subsequent owner.

Carbon Monoxide Alarm

User’s Guide

900-0235

and 

900-0234

KN-COB-DP-LS-CA

Carb

on M

ono

xide

Alar

m

Carb

on M

ono

xide

Alar

m

SINGLE STATION CARBON

MONOXIDE ALARM

AC Plug-in Operated with 9 V Battery Backup

KN-COP-DP-LS-CA

with Digital Display

900-0234

900-0235

Содержание 900-0234

Страница 1: ...be saved for future reference and passed on to any subsequent owner Carbon Monoxide Alarm User s Guide 900 0235 and 900 0234 KN COB DP LS CA Carbon Monoxide Alarm Carbon Monoxide Alarm SINGLE STATION...

Страница 2: ...2 Call your emergency services Fire Department or 911 Never restart the source of a CO problem until it has been corrected Never ignore the sound of the alarm If the alarm is sounding pressing the tes...

Страница 3: ...ke alarm is alarming in a non emergency situation Because your sense of sight smell hearing and touch give you information you can almost instantly judge what action to take if you hear your smoke ala...

Страница 4: ...It may not fully safeguard individuals with specific medical conditions If in doubt consult a medical practitioner Individuals with medical problems may consider using warning devices which provide au...

Страница 5: ...CO poisoning indicate that while victims are aware they are not well they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance Also young...

Страница 6: ...When the Alarm Sounds inside front cover Low Levels Generally below 50 PPM Kidde recommends you take action to eliminate the source of CO See What to do When the Alarm Sounds inside front cover IMPOR...

Страница 7: ...oose from clothes dryers furnaces or water heaters Obstructions in or unconventional vent pipe designs which can amplify the above situations Extended operation of unvented fuel burning devices range...

Страница 8: ...ronic device CO alarms are not fool proof CO alarms have a limited operational life You must test your CO alarm weekly because it could fail to operate at any time If your CO alarm fails to test prope...

Страница 9: ...button while the unit is removed from the plug to allow the battery to be changed without the 85dB alarm sounding The feature can also be disabled by pressing in the Tamper Resist Activation switch a...

Страница 10: ...chance to replace the battery at a more convenient time without sacrificing your safety by disconnecting the alarm from power During this Low Battery HUSH period your alarm is monitoring for CO IMPORT...

Страница 11: ...the sensor to substances that could damage or contaminate it Do not install in areas where the temperature is colder than 4 4 C 40 F or hotter than 37 8 C 100 F such as crawl spaces attics porches and...

Страница 12: ...DIRECT PLUG 5 Alarm Characteristics Carbon Monoxide Alarm Indicator When the alarm senses a dangerous level of CO the unit will emit a loud alarm pattern The alarm pattern is 4 quick beeps followed by...

Страница 13: ...CO and with a good battery None Normal Operation Green LED flashes every 7 seconds None Normal DC operation on 9V battery backup Verify AC power is restored as soon as possible to conserve battery Re...

Страница 14: ...eps 5 seconds silence repeating every 60 secs Alarm condition powered on battery backup Dangerous concentrations of CO detected Refer to What to do When the Alarm Sounds inside front cover Replace bat...

Страница 15: ...Press the Peak Level button with the button still pressed press the Test Reset button for two seconds and release The number on the display will turn to 0 the memory will be cleared and the alarm wil...

Страница 16: ...ible beep If this happens the battery must be replaced For the 900 0234 with digital display Lb will be displayed alternately with the current CO reading once every second To replace battery Remove th...

Страница 17: ...ve the CO Alarm to a remote location to prevent possible damage or contamination of the sensor prior to performing any of the following Staining or stripping floors or furniture painting or wall paper...

Страница 18: ...d warranties of description merchantability and fitness for a particular purpose are limited in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of th...

Страница 19: ...mited in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or...