background image

INSTRUCTIONS PERTAINING TO A RISK OF FIRE,OR INJURY TO 

PERSONS

IMPORTANT SAFETY INSTRUCTIONS

Lighted lamp is HOT!

WARNING — To reduce the risk of FIRE OR INJURY TO PERSONS.

1)  Turn off / unplug and allow to cool before replacing lamp.

2)  Lamp gets HOT quickly! Contact only switch / plug when turning on.

3)  Do not touch hot lens or cowl.

4)  Do not remain in light if skin feels warm. (Light is intense, it may cause  

 “sunburn”.)

5)  Do not look directly at lighted lamp.

6)  Keep lamp away from materials that may burn.

7)  Use only with wattage and lamp marked on fixture.

8)  Do not touch the inner glass envelope of the lamp at any time. Use a soft cloth.  

 

Oil from skin may damage lamp.

9)  Do not operate the fixture with a damaged or missing lens.

FOR USE WITH LANDSCAPE LIGHTING SYSTEMS ONLY.

1)  The device is accepted as a component of a landscape lighting system 

 

where the suitability of the CSA or UL labeled combination shall be deter

 

mined by CSA, UL respectively or the local inspection authorities having 

 jurisdiction.

2)  Fixture shall be connected to an extra low voltage transformer approved  

 

for use with landscape lighting systems.

3)  This fixture is to be connected to a secondary wiring of the following type:

 

 

12 GA 60°C minimum type;

 

 

SPT-3 suitable for outdoor use; or

 

 

approved landscape lighting cable.

CAUTION

WHEN INSTALLING KICHLER LANDSCAPE LIGHTING (LINE VOLTAGE OR LOW VOLTAGE), 

CARE SHOULD BE TAKEN TO KEEP CLEAR OF POTENTIALLY COMBUSTIBLE MATERIALS.

WHEN MAINTAINING THE FIXTURES, BE SURE TO REMOVE LEAVES, PINE NEEDLES, 

GRASS CLIPPINGS, MULCH, OR ANY DEBRIS THAT HAS ACCUMULATED ON THE LIGHT 

BULB, LENS, OR BODY OF THE FIXTURE.

WELL / ACCENT LIGHT ASSEMBLY 

FIXTURE IS SUITABLE FOR OUTDOOR USE ONLY

1)  Well / accent light can be installed two different ways.

 

  A)  If accent light is to be used for direct uplighting, dig hole 15” deep.

 

  B)  If accent light is to be used for wall washing, dig hole 9-1/2” deep.

 

These dimension will make hole deep enough to accommodate sleeve  

 

plus 6” of pea gravel to insure proper drainage.

2)  Fill bottom of hole with 6” of pea gravel.

3)  Set sleeve in hole.

 

  A)  Direct uplighting: Angled end down. (Not illustrated)

 

  B)  Wall washing: Angled end up. (Illustrated)

4)  Using denatured alcohol clean both sides of yoke where rubber pads are  

 

to be taped. Denatured alcohol will remove any oil, dirt or residue that may  

 

keep rubber pads from sticking.

5)  Remove paper backing from rubber pads and stick to yoke.

6)  Slip O-ring over accent body and into O-ring groove closest to center of  

 

accent body.

7)  Slip second O-ring into O-ring groove farthest from center of accent body.

8)  Install MR16 lamp (not supplied) into socket inside accent body.

 

NOTE: Use caution when assembling. Hold lamp by outer housing. 

 

DO NOT touch glass envelope inside. If this happens, clean bulb with  

 

denatured alcohol and a lint free cloth.

9)  Assemble cowl with lens to accent body. Secure in place using either the  

 

provided thumbscrew or the vandal resistant screw. NOTE: Vandal  

 

resistant screw requires a 3/32 hex key (Not Provided) for installation or  

 removal.

10) Unscrew phillips head screws in yoke enough to slip cowl between rubber  

 pads.

11)  Tighten phillips head screws until cowl is held securely in place.

12) Guide wire from accent body under bottom of sleeve and back up between  

 

sleeve and soil.

13) Slip yoke hook over edge of sleeve to support accent light.

14) Fill gaps surrounding outside of sleeve with soil.

15) Make wire connections using supplied Quic Disc

 following instructions  

 

below, or using other approved wiring connection method (not supplied.)

Date Issued: 12/2/11

IS-15092-CB

OUTDOOR USE ONLY

DOM ETRE INSTALLE A L’EXTERIEUR

INSTRUCTIONS

For Assembling and Installing Fixtures in Canada

Pour L’assemblage et L’installation Au Canada

For warranty information please visit: http://www.landscapelighting.com/portal/warranty_page

Pour de plus amples informations sur la garantie, cliquez sur le lien ci-dessous : http://www.landscapelighting.com/portal/warranty_page

QUIC DISC

 WIRING INSTRUCTIONS

Turn off power.

The full length of the 18 GA fixture wire may be used to connect with the 10 GA or 12 GA cable provided the following conditions are met:

•  Wiring is to be protected by routing close to the fixture or accessory or secured to a building structure such as house or deck.

•  18 GA fixture wiring is to be cut off so that it is attached to the connector within 6 inches of the fixture or building structure.

•  If it is necessary to make the connections underground, then no more than 6 inches of the 18 GA fixture wire is to be buried.

The Quic Disc

 connector is designed to install one fixture and accommodates one 18 GA fixture wire and one 10 GA or one 12 GA supply wire.

Place the 10 gauge supply wire across the area marked 10 GA on Quic Disc

 or place the 12 gauge supply wire across the area marked 12 GA 

on Quic Disc

.

Place the 18 gauge fixture wire across the area marked 18 GA on the Quic Disc

. After the wires are in place, connecta the top of the Quic 

Disc

 to the base with supplied screw, making sure that the wires remain flat in the bottom portion of the Quic Disc

, and the screw is tightened 

all the way down.

The copper contacts will automatically pierce the wires’ insulation. Excess 18 GA fixture wire that sticks out the end of the Quic Disc

 is to be cut off.

Make no other wiring connections to the 18 GA fixture wire.

HOOK

CROCHET

YOKE

COLLET

RUBBER PAD

COUSSINET DE

CAOUTCHOUC

LENS

LENTILLE

COWL

CAPOT

THUMB SCREW

VIS A AILETTES

O-RING

JOINT TORIQUE

O-RING GROOVE

RAINURE DU JOINT

TORIQUE

ACCENT BODY

CORPS D’ACCENT

SLEEVE

MANCHON

Отзывы: