Assembly instructions
SIEGENIA access control systems
IO module/IO module smart
17/24
05.2020
H39.ELEKS010EN-00
9.4
IO module/IO module smart in master mode
9.4.1
In combination with SIEGENIA ACS
The IO module/IO module smart communicates digitally via the SI-BUS log with the SIEGENIA ACS. The IO module
takes.over.the.master.function..Up.to.3.slave.components.(SIEGENIA.ACS).can.be.operated.in.a.BUS.system..The.
last.slave.component.must.terminate.the.BUS.system.via.a.termination.plug.(included.in.delivery).
IO module in combination with SIEGENIA ACS and
top-hat rail power supply via SI-BUS
IO module with SIEGENIA ACS and
top-hat rail power supply via 12-pin connection terminal strip
Class 2 output
Art.No. 3509884
100-240VAC
24-28VDC/2.5-2.14A
DC OK
+
V V V V
+
-
-
V.ADJ
Ein Unternehmen der SIEGENIA GRUPPE
L
N
Schutzleiter (PE) &
Abschirmung anschliessen
Connect Shield &
Earth-Connection (PE)
1
2
4
3
Class 2 output
Art.No. 3509884
100-240VAC
24-28VDC/2.5-2.14A
DC OK
+
V V V V
+
-
-
V.ADJ
Ein Unternehmen der SIEGENIA GRUPPE
L
N
Schutzleiter (PE) &
Abschirmung anschliessen
Connect Shield &
Earth-Connection (PE)
1
2
4
3
Item
Name
1
SIEGENIA.ACS.(fingerprint.scanner,.keypad,.transponder).on.the.SI-BUS
2
Top-hat.rail.power.supply;.for.12-pin.connection.terminal.strip:
Top-hat rail power supply
connection
IO module connection
V+
24V DC (+) In
V-
24V DC (-) In
3
12-pin.Connection.terminal.strip.for.connection.of.e.g..garage.door.drive,.E-opener,.motorised.door.drive:
1/2.=.potential-free.input.contact.1
3/4.=.potential-free.input.contact.2
5/6.=.potential-free.output.contact.1
7/8.=.potential-free.output.contact.2
9/10.=.potential-free.output.contact.3
11 = 24 V DC (-) In
12 = 24 V DC (+) in
4
IO module