TROUBLESHOOTING TIPS

Solution

Problem

Dirty air filter- air restricted. Clean air filter. Refer to Care and Cleaning section.

Unit recently turned on in hot room. Allow additional time to remove  Stored heat  from 
walls, ceiling, floor and furniture.

Air conditioner 
cooling, but room
is too warm- NO 
ice forming on 
cooling coil behind 
decorative front.

Temperature is set too High, set temperature to a Lower setting.

Air directional louvers positioned improperly. Position louvers for better air distribution.

Front of units is blocked by drapes, blinds, furniture, etc. - restricts air distribution. 
Clear blockage in front of unit.

Doors, windows, registers, etc. Open- cold air escapes. Close doors, windows, registers.

Air conditioner turns on
and off rapidly

Noise when unit is 
cooling

Water dripping
INSIDE when
 unit is cooling.

Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. 
Refer to installation instructions - check with installer.

Dirty air filter- air restricted. Clean air filter.

Air movement sound. This is normal . If too loud, set to a slower  FAN setting.

Outside temperature extremely hot. Set FAN speed to a Higher setting to bring air past 
cooling coils more frequently.

Window vibration - poor installation. Refer to installation instructions or check with installer.

Water dripping
OUTSIDE when
 unit is cooling.

Remote Sensing 
Deactivating 
Prematurely
(some models)

Remote control not located within range. Place remote control  within 20 feet & 180 , 
radius of the front of the unit.

Remote control signal obstructed. Remove obstruction.

Room too cold

Set temperature too low. Increase set temperature.

Unit removing large quantity of moisture from humid room. This is normal during 
excessively humid days.

14

Содержание R-KSTHW08A

Страница 1: ...oner please read this manual carefully and keep it for future reference TABLE OF CONTENTS Installation Instructions 10 4 9 Normal Sounds Important Safety Instructions 1 3 Troubleshooting Tip 13 14 Air...

Страница 2: ...xcess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explos...

Страница 3: ...ters maycause failure It contains contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as wax or thinner but use a soft cloth...

Страница 4: ...he window is a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditioner has been securely and correctly installed according to the in...

Страница 5: ...required tools and parts before starting installation Read and follow the instructions provided with any tools listed here TOOLS NEEDED Flat blade and Phillips screwdrivers Tape measure Level Drill a...

Страница 6: ...harp instruments rubbing alcohol flammable fluids or abrasive cleaners to remove tape or glue These products can damage the surface of your air conditioner Handle the air conditioner gently 1 Remove t...

Страница 7: ...conditioner cabinet lining up the three holes in the top channel with the three holes on top of the air conditioner cabinet 3 Using three pan head Phillips thread cutting screws attach the top channe...

Страница 8: ...to drill one hole through the hole in the middle of top rail and into the window frame Attach cabinet to window with one 10 x 3 4 or 1 2 round head Phillips screw FIG 11 Place two safety locks into t...

Страница 9: ...ront of panel with front panel screws FIG 17 8 Plug into a grounded 3 prong outlet 9 Press RESET on the power supply cord Through the Wall Cabinet Installation Option 1 wood metal or plastic molding W...

Страница 10: ...n to the outside The cabinet should slop at least half a bubble towards the rear 4 Reuse the insulation to seal opening between cabinet and frame 5 Use existing holes in sides and top of cabinet and s...

Страница 11: ...ill be automatically maintained O O O O anywhere between 62 F 17 C and 86 F 30 C If you want the display to read the actual room temperature see To Operate on Fan Only section Sound of Rushing Air At...

Страница 12: ...selected temperature This ends the Sleep mode and the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by pressing the Sleep...

Страница 13: ...during this time The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Left and Right Temp Timer buttons at the...

Страница 14: ...of defective workman ship or materials in this appliance Solution Air conditioner does not start Wall plug disconnected Push plug firmly into wall outlet House fuse blown or circuit breaker tripped Re...

Страница 15: ...ing Water dripping INSIDE when unit is cooling Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer to installation instructions check with installer Dirty...

Отзывы: