background image

EPI

2

 Quarter-turn Electric Actuators 

Instruction and operating manual 

 

 

 
 
 
 
 

EPI

2

-MAN-652NA-OM1 

 

I/O Module 

User’s Manual

 

 
 
 

 

2 NA 

June 07 

N.A Version revision 2 

T.K. 

 

2 NA 

May 07 

 of N.A Version revision 1 

T.K. / D. L. P. 

 

2 NA 

Sept. 06 

N.A Version Created 

T.K. / D. L. P. 

 

2 Jun 

06 

Revision 

A.G.  G.A. 

1 Feb 

06 

Revision 

A.G.  G.A. 

Sept 2005 

First Issue 

A.G. 

G.A. 

Rev. Date 

DESCRIPTION Prepared 

Approved 

 

Note: 
Tyco Valves & Controls has taken every care in collecting and verifying the documentation 
contained in this Instruction and Operating Manual. 
 
The information herein contained is reserved property of Tyco Valves & Controls. 

® Copyright by Tyco Valves and Controls. All rights reserved. 
A tyco International Ltd. Company 

 

1

Содержание EPI2-MAN-652NA-OM1

Страница 1: ...L P 2 Jun 06 Revision A G G A 1 Feb 06 Revision A G G A 0 Sept 2005 First Issue A G G A Rev Date DESCRIPTION Prepared Approved Note Tyco Valves Controls has taken every care in collecting and verifyin...

Страница 2: ...d operating manual INDEX OPTIONAL MODULE 1 OM1 3 INSTALLATION 3 SETTING AND CONFIGURATION 6 MONITOR RELAY FUNCTIONALITY AND SETTING 10 1 OM1 WIRING DIAGRAM 11 Copyright by Tyco Valves and Controls All...

Страница 3: ...ion for loss of power over torque alarm motor over temperature alarm and travel alarm and selector switch position Motor running 4 additional SPST output contacts that can be set independently at 10 l...

Страница 4: ...t ribbon cable to connector J9 on the OM1 card to connector J8 on the logic card in the actuator Figures 6 and 7 Connector J9 Connector J8 Fig 6 Fig 7 Connect the 8 pin connector to connector J3 on th...

Страница 5: ...t the 3 pin connector to connector J6 on the OM1 card figure 11 3 pin connector 2 pin connector Fig 10 Fig 11 Install the three metal spacers Models E006 and E013 only Place the OM1 card onto the supp...

Страница 6: ...NA or MAN 652NA_SG Important Please note that the settings may be performed in any order OM1 settings are changed using the following controls see fig 19 Enter configuration mode dip switch SW4 Functi...

Страница 7: ...to ON See item 13 in the table above To modify functions 1 through 13 proceed as follows 1 Enter setup configuration mode move SW4 switch to the ON position 2 Choose the setting to be modified from th...

Страница 8: ...below move SW3_1 to the OFF position SW3_2 to the ON position and SW5 to the ON position 6 Exit configuration mode move SW4 to position 1 The impedance is 250 Ohm SW5 SW3 Fig 20 Selecting 4 20 mA or 0...

Страница 9: ...3 0 Inactive 3 1 0 3 2 12 5 3 3 25 3 4 37 5 3 5 50 3 6 62 5 3 7 75 3 8 87 5 3 9 100 Relay AUX1 Setting Relay 3 SW8 SW7 Action 0 0 Inactive 0 1 0 0 2 12 5 0 3 25 0 4 37 5 0 5 50 0 6 62 5 0 7 75 0 8 87...

Страница 10: ...communication 10 Over stroke exceeds 5 to 95 of travel 11 Bluetooth TM failure if present The monitor relay contacts can be set to make or break by soldering the pins of connection J1 J1 2 3 1 Defaul...

Страница 11: ...lectric Actuators Instruction and operating manual 1 OM1 WIRING DIAGRAM 5 4 20 mA OR 0 10VDC to be selected on the OM1 board Copyright by Tyco Valves and Controls All rights reserved A tyco Internatio...

Страница 12: ...EPI2 Quarter turn Electric Actuators Instruction and operating manual Copyright by Tyco Valves and Controls All rights reserved A tyco International Ltd Company 12...

Отзывы: