![Keysight U3606A Скачать руководство пользователя страница 178](http://html.mh-extra.com/html/keysight/u3606a/u3606a_users-and-service-manual_1961516178.webp)
5
Verification and Performance Tests
Performance Verification Tests
156
U3606A User’s and Service Guide
Table 5-2
Zero offset verification test
Input
Function
Range
Error from
nominal 1 year
Short
DC voltage
100 mV
±0.008 mV
1 V
±0.00005 V
10 V
±0.0005 V
100 V
±0.005 V
1000 V
±0.05 V
Resistance
100
Ω
±0.008
Ω
1 k
Ω
±0.00005 k
Ω
10 k
Ω
±0.0005 k
Ω
100 k
Ω
±0.005 k
Ω
1 M
Ω
±0.00005 M
Ω
10 M
Ω
±0.0005 M
Ω
100 M
Ω
±0.005 M
Ω
Open
DC current
10 mA
±0.0015 mA
100 mA
±0.005 mA
1 A
±0.00007 A
3 A
±0.00021 A