:SEARch Commands
26
Keysight P9241/42/43A Oscilloscopes SCPI Programmer's Guide
823
:SEARch:SERial:CAN:MODE
Command Syntax
:SEARch:SERial:CAN:MODE <value>
<value> ::= {IDEither | IDData | DATA | IDRemote | ERRor | ACKerror
| FORMerror | STUFferror | CRCerror | ALLerrors | OVERload
| MESSage | MSIGnal}
The :SEARch:SERial:CAN:MODE command selects the type of CAN information to
find in the Lister display:
Query Syntax
:SEARch:SERial:CAN:MODE?
The :SEARch:SERial:CAN:MODE? query returns the currently selected mode.
Return Format
<value><NL>
<value> ::= {IDE | IDD | DATA | IDR | ERR | ACK | FORM | STUF | CRC
| ALL | OVER | MESS | MSIG}
See Also
•
, “:SEARch Commands,” starting on page 785
•
":SEARch:SERial:CAN:PATTern:DATA"
•
":SEARch:SERial:CAN:PATTern:ID"
Condition
Front-panel name
Description
IDEither
Frame ID
Finds remote or data frames matching the specified ID.
IDData
Data Frame ID
Finds data frames matching the specified ID.
DATA
Data Frame ID and Data
Finds data frames matching the specified ID and data.
IDRemote
Remote Frame ID
Finds remote frames with the specified ID.
ERRor
Error Frame
Finds CAN active error frames.
ACKerror
Acknowledge Error
Finds the acknowledge bit if the polarity is incorrect.
FORMerror
Form Error
Finds reserved bit errors.
STUFferror
Stuff Error
Finds 6 consecutive 1s or 6 consecutive 0s, while in a
non-error or non overload frame.
CRCerror
CRC Field Error
Finds when the calculated CRC does not match the
transmitted CRC.
ALLerrors
All Errors
Finds any form error or active error.
OVERload
Overload Frame
Finds CAN overload frames.
MESSage
Message
Finds a symbolic message.
MSIGnal
Message and Signal
(non-FD)
Finds a symbolic message and a signal value.
Содержание P9241
Страница 1: ...Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Страница 6: ...6 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Страница 36: ...36 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 1 What s New...
Страница 41: ...Setting Up 2 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 41...
Страница 44: ...44 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 2 Setting Up...
Страница 222: ...222 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 7 Root Commands...
Страница 244: ...244 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 8 ACQuire Commands...
Страница 256: ...256 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 9 CALibrate Commands...
Страница 278: ...278 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 10 CHANnel n Commands...
Страница 328: ...328 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 15 EXTernal Trigger Commands...
Страница 386: ...386 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 17 FUNCtion m Commands...
Страница 390: ...390 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 18 HCOPY Commands...
Страница 416: ...416 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 20 MARKer Commands...
Страница 498: ...498 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 21 MEASure Commands...
Страница 532: ...532 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 22 MTESt Commands...
Страница 572: ...572 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 24 SAVE Commands...
Страница 596: ...596 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 25 SBUS n Commands SBUS n A429 SOURce on page 588...
Страница 900: ...900 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 28 TIMebase Commands...
Страница 1080: ...1080 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 31 WGEN w Commands...
Страница 1142: ...1142 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 34 Error Messages...
Страница 1204: ...1204 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 37 More About Oscilloscope Commands...
Страница 1344: ...1344 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide Index...