Keysight N9923-90001 User’s Guide
95
DTF (Distance to Fault) Measurements
DTF Measurement Settings
— Press
Meas Setup 4
.
— Then
DTF Cable Specifications
— Select
Cable Corr
—
Auto
Use Cable Loss and Velocity Factor values from a Cable file. See
“How to Edit, Save, and Recall a Cable File” below. This will overwrite
a manually-entered value.
—
Man
(Default setting) Manually enter a value for Cable Loss and
Velocity Factor.
— Then:
—
Velocity Factor
Using the numeric keypad, enter a value between 0.01
and 1. Then press
Enter
.
—
Cable Loss
Using the numeric keypad, enter a positive Cable Loss
value in dB/m, then press
Enter
.
How to Edit a Cable File
The FieldFox includes many predefined cable files with the manufacturer’s
specifications. You can edit these files or create new cable files using the
following procedure or using the FieldFox Data Link Software.
The Cable correction data survives a Mode Preset and Preset.
With a DTF measurement present:
— Press
Meas Setup 4
— Then
DTF Cable Specifications
— Then
Edit/Save/Recall Cables
— Press
New Cable
then
Yes
to clear all data from the existing DTF Cable
table and reset header information to default settings.
— Then
Edit Cable
to open the Cable Editor.
— Then use the
arrows to select a field,
—When editing Cable Description information, press
Edit
then modify
the selected field using the FieldFox labeler.
—When editing Frequency/Loss pairs, enter numbers using the numeric
keypad, then select a frequency suffix. Then
Enter
. Learn more about
“How the Freq/Loss pairs are applied” below.
— Optionally choose from the following:
—
Previous / Next Page
Quickly scrolls through pages of Freq/Loss data.
—
Add Data
Add a blank Freq/Loss pair to the table,
—
Delete/Clear
then:
Содержание N9923A
Страница 1: ...Keysight Technologies FieldFox RF Network Analyzers N9923A User s Guide ...
Страница 14: ...14 Keysight N9923 90001 User s Guide Contents ...
Страница 20: ...20 Keysight N9923 90001 User s Guide Overview FieldFox Manuals Software and Supplemental Help ...
Страница 36: ...36 Keysight N9923 90001 User s Guide Preparing for Initial Use of Your New FieldFox Connector Care ...
Страница 60: ...60 Keysight N9923 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Страница 100: ...100 Keysight N9923 90001 User s Guide DTF Distance to Fault Measurements DTF Measurement Settings ...
Страница 124: ...124 Keysight N9923 90001 User s Guide Calibration for NA CAT and VVM Modes Calibration Method Summary ...
Страница 134: ...134 Keysight N9923 90001 User s Guide Power Meter USB Mode USB Power Meter Settings ...
Страница 144: ...144 Keysight N9923 90001 User s Guide Frequency Offset Using Power Sensor FOPS Option 208 FOPS Settings ...
Страница 160: ...160 Keysight N9923 90001 User s Guide Pulse Measurements Mode Option 330 Pulse Measurement Settings ...
Страница 206: ...206 Keysight N9923 90001 User s Guide File Management Printing ...
Страница 246: ...246 Keysight N9923 90001 User s Guide Working with the Lithium Ion Battery Lithium Ion Battery Disposal ...
Страница 264: ...264 Keysight N9923 90001 User s Guide Specifications Data Sheet ...
Страница 267: ...267 Keysight N9923A Handheld Analyzer User s Guide D Korean Battery Safety Translation ...
Страница 268: ...268 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Страница 269: ...Keysight N9923 90001 User s Guide 269 Korean Battery Safety Translation ...
Страница 270: ...270 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Страница 275: ...Installation Note Xxxxx xxxxx 3 ...