Keysight N9923-90001 User’s Guide 137
Frequency Offset Using Power Sensor (FOPS) – Option 208
Overview
Overview
This feature allows the FieldFox source frequency to be set independently from
the power sensor (receiver) frequency. With frequency offset using power
sensor (FOPS), the frequency of both the source and receiver are swept, and
the two track each other. The offset frequency can be negative, zero, or
positive.
FOPS can be used to characterize the scalar transmission response of devices
such as mixers and converters. This frequency offset capability is necessary for
conversion loss/gain measurements on frequency-translating devices since, by
definition, the input and output frequencies of the DUT are different. The
FieldFox source stimulates the DUT and the power sensor is used as the
measurement receiver.
Since power sensors are inherently broadband devices (not
frequency-selective), it is your responsibility to ensure that ONLY the signal of
interest is present at the power sensor input and that all others signals are
filtered appropriately.
For some DUTs, the output frequency may sweep in a reverse direction, as
compared to the source frequency. The FieldFox analyzer includes an offset
calculator that ensures a fast measurement setup.
The following shows a typical use case for FOPS:
— The DUT is a long section of cable and a frequency converter.
— The FieldFox source is tuned to the RF frequency.
— The USB power sensor, with an equally long USB/LAN cable, is connected
to the IF Output. USB/LAN extenders are NOT provided with the FieldFox or
Keysight USB power sensors.
— Conversion gain/loss is measured at power sensor.
Содержание N9923A
Страница 1: ...Keysight Technologies FieldFox RF Network Analyzers N9923A User s Guide ...
Страница 14: ...14 Keysight N9923 90001 User s Guide Contents ...
Страница 20: ...20 Keysight N9923 90001 User s Guide Overview FieldFox Manuals Software and Supplemental Help ...
Страница 36: ...36 Keysight N9923 90001 User s Guide Preparing for Initial Use of Your New FieldFox Connector Care ...
Страница 60: ...60 Keysight N9923 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Страница 100: ...100 Keysight N9923 90001 User s Guide DTF Distance to Fault Measurements DTF Measurement Settings ...
Страница 124: ...124 Keysight N9923 90001 User s Guide Calibration for NA CAT and VVM Modes Calibration Method Summary ...
Страница 134: ...134 Keysight N9923 90001 User s Guide Power Meter USB Mode USB Power Meter Settings ...
Страница 144: ...144 Keysight N9923 90001 User s Guide Frequency Offset Using Power Sensor FOPS Option 208 FOPS Settings ...
Страница 160: ...160 Keysight N9923 90001 User s Guide Pulse Measurements Mode Option 330 Pulse Measurement Settings ...
Страница 206: ...206 Keysight N9923 90001 User s Guide File Management Printing ...
Страница 246: ...246 Keysight N9923 90001 User s Guide Working with the Lithium Ion Battery Lithium Ion Battery Disposal ...
Страница 264: ...264 Keysight N9923 90001 User s Guide Specifications Data Sheet ...
Страница 267: ...267 Keysight N9923A Handheld Analyzer User s Guide D Korean Battery Safety Translation ...
Страница 268: ...268 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Страница 269: ...Keysight N9923 90001 User s Guide 269 Korean Battery Safety Translation ...
Страница 270: ...270 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Страница 275: ...Installation Note Xxxxx xxxxx 3 ...