Keysight N9923-90001 User’s Guide 133
Power Meter (USB) Mode
USB Power Meter Settings
—
Single
Automatically sets Continuous OFF and causes FieldFox to
make ONE measurement, then hold for the next
Single
key press.
When a data trace is displayed, the entire trace is measured, then
holds. The
Hold
annotation changes to an arrow --> while the
measurement occurs.
—
Continuous
Makes continuous measurements. This is the typical
setting when battery power is not critical.
You can also use
Run / Hold +/-
to toggle between Single and Continuous.
Step Detection Mode
The FieldFox supports the Step Detection feature that is present in Keysight
USB power sensors. When enabled, this feature reduces settling time after a
significant step in the measured power. For more information, please refer to
the USB Power Meter documentation.
How to set Step Detection mode
— Press
Meas Setup 4
.
— Then
Step Detection OFF ON
— Then choose from the following:
—
ON
Enables step detection (default setting)
—
OFF
Disables step detection
Limits
In Power Meter Mode, Minimum and Maximum limits set a visible range of
acceptable readings between these two values. Readings that are below the
minimum or above the maximum are clearly visible on the power meter display.
How to set Limits
— Press
Limit 8
.
— Then choose from the following:
—
Min Limit OFF ON
Toggles the display of the Minimum limit ON and
OFF.
—
Min Limit Value
Sets the Minimum limit power value. Power reading
lower than this will exceed the limit.
—
Max Limit OFF ON
Toggles the display of the Maximum limit ON and
OFF.
—
Max Limit Value
Sets the Maximum limit power value. Power reading
higher than this will exceed the limit.
Содержание N9923A
Страница 1: ...Keysight Technologies FieldFox RF Network Analyzers N9923A User s Guide ...
Страница 14: ...14 Keysight N9923 90001 User s Guide Contents ...
Страница 20: ...20 Keysight N9923 90001 User s Guide Overview FieldFox Manuals Software and Supplemental Help ...
Страница 36: ...36 Keysight N9923 90001 User s Guide Preparing for Initial Use of Your New FieldFox Connector Care ...
Страница 60: ...60 Keysight N9923 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Страница 100: ...100 Keysight N9923 90001 User s Guide DTF Distance to Fault Measurements DTF Measurement Settings ...
Страница 124: ...124 Keysight N9923 90001 User s Guide Calibration for NA CAT and VVM Modes Calibration Method Summary ...
Страница 134: ...134 Keysight N9923 90001 User s Guide Power Meter USB Mode USB Power Meter Settings ...
Страница 144: ...144 Keysight N9923 90001 User s Guide Frequency Offset Using Power Sensor FOPS Option 208 FOPS Settings ...
Страница 160: ...160 Keysight N9923 90001 User s Guide Pulse Measurements Mode Option 330 Pulse Measurement Settings ...
Страница 206: ...206 Keysight N9923 90001 User s Guide File Management Printing ...
Страница 246: ...246 Keysight N9923 90001 User s Guide Working with the Lithium Ion Battery Lithium Ion Battery Disposal ...
Страница 264: ...264 Keysight N9923 90001 User s Guide Specifications Data Sheet ...
Страница 267: ...267 Keysight N9923A Handheld Analyzer User s Guide D Korean Battery Safety Translation ...
Страница 268: ...268 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Страница 269: ...Keysight N9923 90001 User s Guide 269 Korean Battery Safety Translation ...
Страница 270: ...270 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Страница 275: ...Installation Note Xxxxx xxxxx 3 ...