Keysight N5227-60121 Скачать руководство пользователя страница 1

Installation 

Note

Keysight - Add 4-Port Capability 
Upgrade Kit 

F

or

 

Version 7 Synthesizer

s

(For Models With Direct Digital Synthesis (Only)

)

To Upgrade PNA N522

7

B Option 200 to Option 400

 

Upgrade Kit 

Order Numbers: N522

7

BU- 660

 

Keysight Kit Number: N522

7

-601

21

Содержание N5227-60121

Страница 1: ...ht Add 4 Port Capability Upgrade Kit For Version 7 Synthesizers For Models With Direct Digital Synthesis Only To Upgrade PNA N5227B Option 200 to Option 400 Upgrade Kit Order Numbers N5227BU 660 Keysight Kit Number N5227 60121 ...

Страница 2: ...o U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula The license set forth in the EULA represents the exclusive authority by which the U S government may use modify distribute or disclose the Software The EULA and the license set forth therein does not require or p...

Страница 3: ...al test port couplers a splitter a 3 dB pad a modified front panel many additional new cables Refer to Overview of the Installation Procedure on page 13 If you had an A model PNA X with Option 219 419 with Option H85 that was upgraded to a B model please refer to Options 217 417 If you had an A model PNA X with Option 224 423 with Option H85 that was upgraded to a B model then refer to Option 222 ...

Страница 4: ...e Web at http www keysight com find assist If you do not have access to the Internet please contact your Keysight field engineer If You Have Problems With the Upgrade Kit Contents Keysight stands behind the quality of the upgrade kit contents If you have problems with any item in the kit refer to www keysight com and the Contact Keysight link In any correspondence or telephone conversation refer t...

Страница 5: ...tp www keysight com find softwaremanager To complete the request you will need to gather the following information The PNA contains extremely sensitive components that can be ruined if mishandled Follow instructions carefully when making cable connections especially wire harness connections The person performing the work accepts responsibility for the full cost of the repair or replacement of dama...

Страница 6: ... option number do not match those on the license message you received from Keysight you will not be able to install the license key file If this is the case you received from Keysight you will not be able to install the license key file If this is the case contact Keysight for assistance Refer to Getting Assistance from Keysight on page 4 Verify the Model Version of HMA26 5 Installed This upgrade ...

Страница 7: ... Click Technical Support Manuals 4 Click Service Manual 5 Click the service guide title to download the PDF file 6 When the PDF of the Service Guide is displayed scroll through the Contents section bookmarks to locate the information needed Protecting Your Workspace from Electrostatic Discharge For information click on the Chapter 1 bookmark Electrostatic Discharge Protection in the PDF Service Gu...

Страница 8: ...orque wrench set to 6 in lbs 0 68 N m 1 N A 5 8 in 16 mm nutsetter or open end torque wrench set to 21 in lbs 2 38 N m 1 N A 9 mm nutsetter or open end torque wrench set to 21 in lbs 2 38 N m 1 N A 1 in 25 4 mm torque wrench set to 72 in lbs 8 15 N m 1 N A Use a 5 16 in torque wrench set to 10 in lbs on all cable connections except the front and rear panel bulkhead connectors On these use a 5 16 i...

Страница 9: ...sembly 1 N5240 60102 A26a Splitter 1 5067 4086 A28 Mixer brick 2 1 5087 7337 A30 Receiver coupler test port 3 2 5087 7744 A31 Receiver coupler test port 4 A34 Coupler test port 3 2 5087 7778 A35 Coupler test port 4 A61 70 GHz doubler assembly test port 3 2 5087 7336 A62 70 GHz doubler assembly test port 4 A69 3 dB attenuator 1 08490 60037 Dress Panel lower 4 port 1 N5240 00009 Pad secured to each ...

Страница 10: ...t 3 4 test port couplers 2 5022 1087 Front panel overlay label 4 port 1 N5227 80024 Test set front plate 4 port 1 N5247 00009 Gap pad between each test coupler and the test set front plate 4 E4403 20033 Cable clamp 5 1400 1334 Cable tie wrap 5 1400 0249 Bracket rear bottom side for semi rigid cables 1 N5247 00006 Bracket for receiver coupler assembly 2 N5247 00005 Bracket for receiver coupler port...

Страница 11: ...multiplexer P411 1 N5242 60021 W73 RF cable A27 mixer brick R2 to A24 IF multiplexer P412 1 N5242 60022 W75 RF cable A28 mixer brick D to A24 IF multiplexer P801 1 N5242 60024 W76 RF cable A28 mixer brick R4 to A24 IF multiplexer P414 1 N5242 60019 W77 RF cable A28 mixer brick R3 to A24 IF multiplexer P413 1 N5242 60020 W78 RF cable A28 mixer brick C to A24 IF multiplexer P601 1 N5242 60023 W80 RF...

Страница 12: ...z doubler J1 2 N5247 60018 Ribbon cable A23 test set motherboard J3 to A62 port 4 70 GHz doubler J1 Ribbon cable A23 test set motherboard J552 to A28 mixer brick 2 J52 1 N5247 60015 a The A26 splitter 5067 4086 and N5247 20111 N5245 20022 N5245 20023 N5247 20110 and N5247 20146 cables are only used with a legacy HMA26 5 p n 5087 7765 The N5240 20125 and N5247 20185 cables are used only with the ne...

Страница 13: ...bler Assembly From the Test Set Deck Step 10 Assemble the A61 70 GHz Doubler on the Doubler Mount Step 11 Reinstall the A60 A61 70 GHz Doubler Assembly Step 12 Remove the A63 70 GHz Doubler Assembly From the Test Set Deck Step 13 Assemble the A62 70 GHz Doubler on the Doubler Mount Step 14 Reinstall the A62 A63 70 GHz Doubler Assembly Step 15 Remove the Old A15 Single Source Direct Digital Synthes...

Страница 14: ...ove and Disassemble the 2 Port Test Set Front Plate Step 33 Install the LED Boards and Test Port Coupler Assemblies to the 4 Port Test Set Front Plate Step 34 Install the 4 Port Coupler Plate Assembly to the Deck Step 35 Install Some Bottom Side Test Set Cables Step 36 Install Cables on IF Multiplexer Board Step 37 Reinstall the Testset Stabilizer Bracket on the A24 IF Multiplexer Board Step 38 Re...

Страница 15: ...e the Outer Cover For instructions click the Chapter 7 bookmark Removing the Covers in the PDF Service Guide Step 3 Remove the Inner Cover For instructions click the Chapter 7 bookmark Removing the Covers in the PDF Service Guide1 Step 4 Remove the Front Panel Jumper Cables and Cable Guards 1 Pull the two cable guards off of the front panel jumper cables Save them for reinstallation later 2 Remove...

Страница 16: ...0121 Installation Procedure for the Upgrade Step 7 Remove the Testset Stabilizer Bracket from the A24 IF Multiplexer Board Remove the stabilizer bracket as shown in Figure 2 Figure 2 Testset Stabilizer Bracket on A24 IF MUX Board ...

Страница 17: ... 2 receiver coupler to A27 mixer brick R W138 N5227 20008 A36 port 2 coupler to A27 mixer brick B W62 N5247 20100 A25 HMA26 5 to A27 mixer brick 4 Remove and save the following semi rigid cables for reinstallation later W12 N5227 20041 A60 port 1 70 GHz doubler to W11 W24 N5247 20061 A63 port 2 70 GHz doubler to W23 W26 N5247 20051 A63 port 2 70 GHz doubler to W25 W14 N5247 20072 A60 port 1 70 GHz...

Страница 18: ...Assembly From the Test Set Deck Remove the 70 GHz doubler 1 assembly from the test set deck For instructions click the Chapter 7 bookmark Removing and Replacing the A60 A63 70 GHz Doublers in the PDF Service Guide1 Keep all parts for reinstallation later Step 10 Assemble the A61 70 GHz Doubler on the Doubler Mount 1 Follow the instruction in Figure 3 to install the A61 70 GHz doubler 3 on the doub...

Страница 19: ...es and then reinstall the A60 A61 70 GHz doubler assembly on the test set deck reusing the existing screws For instructions click the Chapter 7 bookmark Removing and Replacing the A60 A63 70 GHz Doublers in the PDF Service Guide1 Step 12 Remove the A63 70 GHz Doubler Assembly From the Test Set Deck Remove the A63 70 GHz doubler 2 assembly from the test set deck For instructions click the Chapter 7...

Страница 20: ... Assemble the A62 70 GHz Doubler on the Doubler Mount 1 Follow the instruction in Figure 5 to install the A62 70 GHz doubler 4 on the doubler mount New parts are listed in Table 1 on page 9 of this document Figure 5 Installing A62 Doubler 4 on the Doubler Mount 5087 7338 0515 0375 ...

Страница 21: ...ssembly N5247 60012 N5247 60013 N5247 60018 1400 0249 Step 14 Reinstall the A62 A63 70 GHz Doubler Assembly Reinstall the A63 70 GHz doubler 2 cables and then reinstall the A62 A63 70 GHz doubler assembly on the test set deck reusing the existing screws For instructions click the Chapter 7 bookmark Removing and Replacing the A60 A63 70 GHz Doublers in the PDF Service Guide1 1 See Downloading the O...

Страница 22: ...bly A Remove the DDS Cables For the semirigid cables follow the two instructions shown in Figure 7 These cables W1 N5240 20124 and W61 N5240 20125 must be saved they will be reinstalled Remove any gray cables connected to the DDS assembly and note their location They will be re connected in Step 23 Install the NEW A15 Dual Source Direct Digital Synthesizer DDS Assembly and Cables Figure 7 Remove t...

Страница 23: ...or the Upgrade B Remove the DDS Assembly Follow the two instructions shown in Figure 8 The x2 DDS assembly will not be reused Figure 8 Remove the Old x2 DDS Assembly Step 16 Install Bracket to A10 Source Assembly Follow the two instructions shown in Figure 9 ...

Страница 24: ...24 Installation Note N5227 90121 Installation Procedure for the Upgrade Figure 9 A10 Source 2 Assembly Bracket Installation 5087 7780 N5247 20136 0515 0375 0515 2178 0515 0666 ...

Страница 25: ...90121 25 Installation Procedure for the Upgrade Step 17 Assemble the A10 26 5 GHz Source 2 Assembly Follow the four instructions shown in Figure 10 Figure 10 A10 Source 2 Assembly 5087 7780 N5245 20032 N5245 20034 N5247 20125 ...

Страница 26: ...ocedure for the Upgrade Step 18 Assemble and Install the A12 40 GHz Doubler Assembly Follow the five instructions shown in Figure 11 Figure 11 A12 40 GHz Doubler 3 Assembly Installation 5087 7346 1810 0118 5247 20096 N5247 20114 N5247 20086 1810 0118 ...

Страница 27: ...90121 27 Installation Procedure for the Upgrade Step 19 Install the A12 40 GHz Doubler Cables Follow the three instructions shown in Figure 12 Figure 12 A12 40 GHz Doubler 3 Assembly Cable Installation N5247 60010 N5247 60011 ...

Страница 28: ...0121 Installation Procedure for the Upgrade Step 20 Assemble and Install the A13 40 GHz Doubler Assembly Follow the five instructions shown in Figure 13 Figure 13 A13 40 GHz Doubler 4 Installation 5087 7346 5247 20114 N5247 20086 ...

Страница 29: ...5227 90121 29 Installation Procedure for the Upgrade Step 21 Install the A13 40 GHz Doubler Cables Follow the three instructions shown in Figure 14 Figure 14 A13 40 GHz Doubler 4 Cable Installation N5247 60012 N5247 60013 ...

Страница 30: ...227 90121 Installation Procedure for the Upgrade Step 22 Install the A10 26 5 GHz Source 2 Assembly and Cables Follow the four instructions shown in Figure 15 Figure 15 A10 Source 2 Assembly Installation N5245 20033 0515 0380 ...

Страница 31: ... 2 Reconnect W1 N5240 20124 to DDS J4 and to Source 1 RF IN 3 Connect cable W2 N5240 20126 between the A8 source 2 board RF IN and the A11 source 2 J6 DDS assembly Tighten the cable connectors to 10 in lbs using a 5 16 in torque wrench reuse W61 N5240 20125 A11 13 5 GHz LO DD synthesizer assembly J5 to A21 HMA26 5 RF IN One end was left connected in A Remove the DDS Cables on page 22 reuse W1 N524...

Страница 32: ...allation Note N5227 90121 Installation Procedure for the Upgrade Figure 16 Install Semirigid Cables to DDS Assembly and Source 1 and Source 2 N5240 20124 N5240 20125 N5240 20126 Torque all cables to 10 in lbs ...

Страница 33: ... 17 on page 33 W69 8120 5063 reuse Rear panel REF IN to A11 DD synthesizer assembly J9 W68 8120 5063 reuse A11 DD synthesizer assembly J10 to rear panel REF OUT W200 N5240 60115 reuse SRC DD synthesizer assembly J16 to SPAM J3 Figure 17 Reinstall Following Flexible Cables to the DDS Assembly Top 8120 5063 x2 1400 0249 and N5240 60115 ...

Страница 34: ...P203 to A12 SPAM board J2 W61 N5242 60014 reuse A20 IF multiplexer board P403 to A12 SPAM board J4 W62 N5242 60024 A20 IF multiplexer board P603 to A12 SPAM board J5 W63 N5242 60016 reuse A20 IF multiplexer board P803 to A12 SPAM board J6 W200 N5240 600115 A11 SRC DD Synthesizer assembly J16 to SPAM J3 Figure 18 Connect One End of the Bottom Flexible IF Multiplexer and Top Flexible Gray Cables to ...

Страница 35: ...tion Procedure for the Upgrade Step 24 Install the Cable Bracket Mount 1 Follow the two instructions shown in Figure 19 New parts are listed in Table 1 on page 9 of this document Figure 19 Cable Bracket Mount Installation N5247 00006 0515 0374 ...

Страница 36: ...uctions click the Chapter 7 bookmark Removing and Replacing the A27 and A28 Mixer Bricks in the PDF Service Guide1 Step 26 Assemble the A28 Mixer Brick Assembly 1 Follow the instruction shown in Figure 20 New parts are listed in Table 1 on page 9 of this document Figure 20 A28 Mixer Brick Assembly 5087 7337 0515 1038 1 See Downloading the Online PNA Service Guide on page 7 ...

Страница 37: ...20110 and N5247 20146 cables are only used with a legacy HMA26 5 p n 5087 7765 The N5240 20125 and N5247 20185 cables are used only with the new N5240 60101 HMA 26 5 Discard any cables that are not used If you are unclear which HMA26 5 assembly your PNA has installed refer to Chapter 7 Repairs and Figure 1 on page 7 and for details on A26 splitter and cabling refer to your option model in Chapter ...

Страница 38: ...and Replacing the A27 and A28 Mixer Bricks in the PDF Service Guide2 New parts are listed in Table 1 on page 9 of this document 1 The A26 splitter 5067 4086 and N5247 20111 N5245 20022 N5245 20023 N5247 20110 and N5247 20146 cables are only used with a legacy HMA26 5 p n 5087 7765 The N5240 20125 and N5247 20185 cables are used only with the new N5240 60101 HMA 26 5 Discard any cables that are not...

Страница 39: ... the Upgrade Step 28 Assemble the A30 and A31 Receiver Coupler Assemblies Follow the instructions shown in Figure 23 and Figure 24 New parts are listed in Table 1 on page 9 of this document Figure 23 A30 Receiver Coupler Assembly 5087 7744 N5247 00011 0403 0179 ...

Страница 40: ... for the Upgrade Figure 24 A31 Receiver Coupler Assembly 5087 7744 N5247 00012 0515 0658 0403 0179 Step 29 Install the A30 and A31 Receiver Coupler Brackets Follow the instruction shown in Figure 25 New parts are listed in Table 1 on page 9 of this document ...

Страница 41: ...Installation Note N5227 90121 41 Installation Procedure for the Upgrade Figure 25 Location of A30 and A31 Receiver Coupler Brackets N5247 00005 0515 0372 ...

Страница 42: ... Procedure for the Upgrade Step 30 Install the A30 and A31 Receiver Coupler Assemblies Follow the instruction shown in Figure 26 New parts are listed in Table 1 on page 9 of this document Figure 26 Location of Receiver Coupler Assemblies 0515 0372 ...

Страница 43: ...Service Guide1 2 Using pliers remove the adhesive bumper on the A33 test port 1 coupler and on the A36 test port 2 coupler 3 Follow the two instructions shown in Figure 27 New parts are listed in Table 1 on page 9 of this document Figure 27 A33 A36 Test Port Coupler Assembly E4403 20033 0460 2725 2087 7778 Step 32 Remove and Disassemble the 2 Port Test Set Front Plate 1 Remove two screws from each...

Страница 44: ... the test set deck Keep the screws to reuse later Step 33 Install the LED Boards and Test Port Coupler Assemblies to the 4 Port Test Set Front Plate Follow the three instructions shown in Figure 28 Figure 28 LED Board Assemblies and Test Port Coupler Assemblies Installation N5240 60058 0515 1521 5087 7778 N5247 60016 ...

Страница 45: ...N5245 20023 N5247 20110 and N5247 20146 cables are only used with a legacy HMA26 5 p n 5087 7765 The N5240 20125 and N5247 20185 cables are used only with the new N5240 60101 HMA 26 5 Discard any cables that are not used If you are unclear which HMA26 5 assembly your PNA has installed refer to Chapter 7 Repairs and Fig ure 1 on page 7 and for details on A26 splitter and cabling refer to your optio...

Страница 46: ...r J4 to A8 40 GHz doubler J500 Semirigid Cables Required for Upgrading to an Option 400 PNA To see images showing the location of these cables click the Chapter 6 bookmark Bottom RF Cables 4 Port Option 400 S N Prefixes 6021 in the PDF Service Guide1 New parts are listed in Table 1 on page 9 W129 N5227 20010 A31 port 4 receiver coupler to A69 3 dB pad on A28 mixer brick R4 As shown in Figure 30 in...

Страница 47: ...upler to A27 mixer brick R2 As shown in Figure 30 install clamp part number 1400 1334 to secure W130 W137 N5227 20013 A35 port 4 coupler to A28 mixer brick D As shown in Figure 30 install clamp part number 1400 1334 to secure 1 The A26 splitter 5067 4086 and N5245 20013 N5245 20022 N5245 20023 N545 20101 and N5245 20150 cables are only used with a legacy HMA26 5 p n 5087 7765 If you are unclear wh...

Страница 48: ... to secure W135 W136 N5227 20014 A34 port 3 coupler to A28 mixer brick C As shown in Figure 30 install clamp part number 1400 1334 to secure W135 W131 N5227 20015 A29 port 1 receiver coupler to A33 port 1 coupler W132 N5227 20016 A30 port 3 receiver coupler to A34 port 3 coupler W133 N5227 20017 A31 port 4 receiver coupler to A35 port 4 coupler W134 N5227 20018 A32 port 2 receiver coupler to A36 p...

Страница 49: ...Installation Note N5227 90121 49 Installation Procedure for the Upgrade Figure 31 Location of Cable Tie to Secure W14 and W18 ...

Страница 50: ...41 A60 port 1 70 GHz doubler to W11 W26 reuse N5247 20051 A63 port 2 70 GHz doubler to W25 W16 N5227 20042 A61 port 3 70 GHz doubler to W15 W28 N5227 20045 A61 port 3 70 GHz doubler to A30 port 3 receiver coupler W20 N5227 20043 A62 port 4 70 GHz doubler to W19 W24 reuse N5247 20061 A63 port 2 70 GHz doubler to W23 W68 N5247 20088 rear panel port RF2 OUT J12 to W67 Install SMA load previously remo...

Страница 51: ...d If you have a legacy HMA26 5 5087 7765 installed you can discard this cable W204 N5247 20185 RF cable A24 mixer brick top connector to A21 HMA25 6 A24 mixer brick top connector See also Verify the Model Version of HMA26 5 Installed on page 6 If your instrument has a legacy HMA26 5 5087 7765 installed You will need to remove the cap that is installed on the HMA26 5 top connector before connecting...

Страница 52: ...N5245 20022 A22 splitter to A23 mixer brick If you have the legacy 5086 7765 HMA26 5 please discard N5247 201851 semi rigid cable Refer to Figure 1 on page 7 See also Verify the Model Version of HMA26 5 Installed on page 6 1 The N5247 20185 cable is used only with instruments that have a newer HMA26 5 installed If your PNA has a legacy 5087 7765 HMA26 5 assembly installed then this cable can be di...

Страница 53: ...xer brick R1 to A24 IF multiplexer P411 W73 N5242 60022 A27 mixer brick R2 to A24 IF multiplexer P412 W74 reuse N5242 60018 A27 mixer brick B to A24 IF multiplexer P201 W75 N5242 60024 A28 mixer brick D to A24 IF multiplexer P801 W76 N5242 60019 A28 mixer brick R4 to A24 IF multiplexer P414 W77 N5242 60020 A28 mixer brick R3 to A24 IF multiplexer P413 W78 N5242 60023 A28 mixer brick C to A24 IF mu...

Страница 54: ...panel s lower dress panel can be replaced the 2 port lower dress panel and the lower front panel label must be removed from the front panel assembly Refer to Figure 33 on page 55 New parts are listed in Table 1 on page 9 1 Remove the 2 Port lower front panel label item 2 Remove the 10 screws save the screws for reuse from the 2 port dress panel and remove the dress panel item and respectively 3 Re...

Страница 55: ...ll Front Panel Assembly For instructions on reinstalling the front panel assembly click the Chapter 7 bookmark Removing and Replacing the Front Panel Assembly in the PDF Service Guide1 Be sure to install the two new screws 0515 1946 in the front panel next to test ports 3 and 4 Torque these screws to 9 in lbs 1 See Downloading the Online PNA Service Guide on page 7 ...

Страница 56: ...the overlay 4 Install front panel jumpers Step 43 Position the Cables and Wires to Prevent Pinching On the top side of the PNA carefully position the grey flex cables so they can t be pinched between the covers and the rails On the bottom side of the PNA carefully fold or push down the ribbon cables and wires so they can t be pinched between the hardware and the outer cover Ribbon cables and wires...

Страница 57: ...y of the USB flash drive More than one license file may be copied to the USB flash drive 3 Insert the USB flash drive to the PNA s USB drive slot Within 5 seconds the PNA should display a small New licenses installed message Else load the license key file s manually move your license file s to C Program Files Agilent licensing It may take Keysight License Manager an extra 5 seconds to enable the l...

Страница 58: ...hen EE default adjust is not sufficient source adjustment IF gain adjustment receiver adjustment receiver characterization IF Response Adjustment Option S93090xA B S93093A B or S93094A B Only These adjustments are described in the PNA Service Guide and in the PNA on line HELP A list of equipment required to perform these adjustments is also found in the service guide If the options have not been e...

Страница 59: ...y and in flash memory files The adjustments listed here generate new correction constants The analyzer must have a backup of this new data in case any of the data becomes corrupted To store the backup data perform these steps Navigate to the EEPROM Backup Utility located at Windows 7 C Program Files x86 Keysight Network Analyzer Service eebackup exe Windows 10 C Program Files Keysight Network Anal...

Страница 60: ...to its specifications has not been verified It is recommended that a full instrument calibration be performed using the analyzer s internal performance test software To view information on the performance test software click the Chapter 3 bookmark Tests and Adjustments in the PDF Service Guide1 Step 48 Prepare the PNA for the User 1 If necessary reinstall front jumper cables 2 Install the cable gu...

Страница 61: ...Installation Note Xxxxx xxxxx 3 ...

Страница 62: ...This information is subject to change without notice Keysight Technologies 2009 2020 Edition 1 October 2020 N5227 90121 www keysight com ...

Отзывы: