background image

16

Keysight N4391A/N4392A Optical Modulation Analyzer, Getting Started

1

Introduction

 

 

Line power requirements

Line power connectors

In accordance with international safety standards, the instrument has a 

three-wire power cable. When connected to an appropriate AC power 

receptacle, this cable earths the instrument cabinet. The type of power 

cable shipped with each instrument depends on the country of destination.

WARNING

Please pay attention to the following laser safety warnings:

Under no circumstances look into the end of an optical cable attached to the 

optical output when the device is operational. The laser radiation can 

seriously damage your eyesight.

Do not enable the laser when there is no fiber attached to the optical output 

connector.

The laser is enabled by the software. The laser is on when the green LED 

above the LO Output connector is lit.

The use of the instruments, such as microscopes or spectacles, with this 

product will increase the hazard to your eyes.

The laser module has built-in safety circuitry which will disable the optical 

output in the case of a fault condition.

Refer servicing

 only

 to qualified and authorized personnel.

CAUTION

The Keysight N4391A Optical Modulation Analyzer complies with overvoltage 

category II and pollution degree 2. It can operate from the single-phase AC 

power source that supplies between 100 V and 240 V (max. voltage fluctuation 

10%) at a frequency in the range of 50 to 60 Hz. The maximum power 

consumption of the optical modulation analyzer is 40 VA (N4391A) or 375 VA 

(N4392A) with all options installed.
Please refer to the documentation for your digital signal analyzer for information 

on its line power requirements.

Содержание N4391A

Страница 1: ...Getting Started Keysight N4391A N4392A Optical Modulation Analyzer...

Страница 2: ...icenses The hardware and or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license Restricted Rights Legend If so...

Страница 3: ...titudes of up to 2000 meters Refer to the specifications tables for the ac mains voltage requirements and ambient operating temperature range Before Applying Power Verify that all safety precautions a...

Страница 4: ...ements The affixed label indicates that you must not discard this electrical electronic product in domestic household waste Product Category With reference to the equipment types in WEEE Directive Ann...

Страница 5: ...Safety symbols 11 Instrument markings 11 Initial Safety Information 14 Line power requirements 16 Environmental Information 17 N4391A N4392A Shipping Contents 18 N4391A Contents 18 N4392A Contents 21...

Страница 6: ...ning the Instrument 56 4 Rack Mount Rack Mounting N4391A Z Series Oscilloscopes 58 5 Technical Specifications Specifications Terms and Conditions N4391A 70 Definitions 70 Specifications Guaranteed 70...

Страница 7: ...nalyzer Getting Started 7 Contents N4392A Specifications 80 N4392A General Characteristics 82 6 Regulatory Information Declaration of Conformity 86 Compliance with German Noise Requirements 88 Complia...

Страница 8: ...8 Keysight N4391A N4392A Optical Modulation Analyzer Getting Started Contents...

Страница 9: ...Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 1 Introduction Documentation 10 General Safety Considerations 11 N4391A N4392A Shipping Contents 18...

Страница 10: ...h contains the information you need to get your Optical Modulation Analyzer running and to perform a first measurement The online help which provides the instructions for use The online help for the 8...

Страница 11: ...The product is marked with this warning symbol when it is necessary for the user to refer to the instructions in the manual The laser radiation symbol This warning symbol is marked on products which h...

Страница 12: ...protection are intact only WARNING No operator serviceable parts inside Refer servicing to qualified service personnel To prevent electrical shock do not remove covers WARNING This is a Safety Class 1...

Страница 13: ...forced convection must be used CAUTION Install the instrument so that the power cords are readily identifiable and is easily reached by the operator This is how the instruments are disconnected They d...

Страница 14: ...FR 1040 10 except for deviations pursuant to Laser Notice No 50 dated 2007 June 24 Laser Safety Laser class 1M label not applied to the product Laser class 1M label A sheet of laser safety labels is i...

Страница 15: ...power 163 mW Numerical aperture 0 1 Beam waist diameter 10 mm N4392A Options 100 310 or 110 310 or 100 300 320 or 110 300 320 or 100 300 310 320 or 110 300 310 320 Options 100 300 or 110 300 or 100 3...

Страница 16: ...t connector The laser is enabled by the software The laser is on when the green LED above the LO Output connector is lit The use of the instruments such as microscopes or spectacles with this product...

Страница 17: ...before switching on the instrument Insert the power cable plug only into a socket outlet provided with a protective earth contact Do not use an extension cord without a protective conductor Using an e...

Страница 18: ...A Contents Contents for all options 1x optical modulation analyzer N4391A 1 to 3x FC APC connector interface quantity depends on options ordered 81000NI 1x language labels sheet 81645 44309 1x torque...

Страница 19: ...ngle scope setup type B N4391 61663 1x optical mouse USB PS2 1150 7799 1x 104 key standard keyboard with USB connector 1150 7896 1x stylus pen cushion grip 1150 7997 1x cable calibration 54916 61626 1...

Страница 20: ...nologies sales office If the shipment was damaged contact the carrier then contact the nearest Keysight Technologies sales office 1x bracket rear for scope type B N4391 04109 2x bracket rear N4391 250...

Страница 21: ...4 61723 1x language labels sheet 81645 44309 1x calibration certificate 9230 0333 1x wrist strap with cord 6 lg blue 9300 1405 1x STYLUS PEN Cushion Grip 5 54 in LG 0 44 in DIA 1150 7997 1x RoHS adden...

Страница 22: ...s missing or defective contact your nearest Keysight Technologies sales office If the shipment was damaged contact the carrier then contact the nearest Keysight Technologies sales office 1x Entitlemen...

Страница 23: ...niium 90000 Z Series High Performance Oscilloscope option M33 Z20 Z25 Z33 on the Optical Test Set 24 Concluding the setup for all options 29 Creating Your First Trace on the OMA 32 How to Reconfigure...

Страница 24: ...optical coherence receiver a Using a Torx T15 screwdriver loosen the screws holding the side panels on the optical coherence receiver b Slide the side panels half way to the rear c Using a Torx T15 sc...

Страница 25: ...r feet N4391 25073 secure rear feet and rear bracket to the rear of the optical coherence receiver 2 Prepare the oscilloscope a Place the oscilloscope upside down and lay it on its top on the work sur...

Страница 26: ...e receiver a Remove the four screws on the bottom rear edge of the oscilloscope This is where the rear bracket on the optical coherence receiver will be secured to the oscilloscope b With the optical...

Страница 27: ...Analyzer Getting Started 27 Getting Started 2 c Using a Torx T10 screwdriver and the screws from the oscilloscope secure the rear bracket of the optical coherence receiver to the rear of the oscillos...

Страница 28: ...ct the RF cables a Connect RF cable N4391 61641 from Port 1 of the optical coherence receiver to Port 1 of the oscilloscope b Connect RF cable N4391 61642 from Port 2 of the optical coherence receiver...

Страница 29: ...e to the other left to right or right to left attach the rigid cables between the digital signal analyzer and the optical modulation analyzer Note you may find this easier if you move the front of the...

Страница 30: ...dulation analyzer Connecting to the optical modulation analyzer with a straight connector will damage it CAUTION Before you connect any fiber optic cable to the Optical Modulation Analyzer please ensu...

Страница 31: ...zer application running on the digital signal analyzer has initialized it the green LED above the laser output indicates whether the laser is emitting radiation The laser is enabled and disabled by th...

Страница 32: ...al polarization signal with a performance that is typically achieved on optical coherent long haul transmitters This signal has incorporated bit errors inserted into the transmitter PRBS generation 1...

Страница 33: ...enter the value The Fine tune symbol Rate selection ensures that the symbol rate is adjusted to within the displayed range 7 Ensure that the Modulation Format is set to QPSK If not select it from the...

Страница 34: ...olarization mode dispersion are deselected 10 Ensure that Use default screen layout is selected to use the default layout which provides a wide variety of results If not selected the current layout wi...

Страница 35: ...Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 35 Getting Started 2...

Страница 36: ...ered options is configured at the factory This section shows how to modify the N4391A standard factory configuration 1 In the Keysight 89600 VSA Software interface select Utilities Hardware Discovered...

Страница 37: ...er Getting Started 37 Getting Started 2 3 Click on the plus button 4 From the Possible Logical Instruments list select Keysight N4391A Optical Modulation Analyzer based on the type of OMA then click o...

Страница 38: ...38 Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 2 Getting Started 5 In the ADC selection click on the down arrow and select the oscilloscope configured with the N4391A...

Страница 39: ...Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 39 Getting Started 2 6 In the Downconverter selection click on the down arrow and select the N4391A...

Страница 40: ...40 Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 2 Getting Started 7 In the Synthesizer selection click on the down arrow and select the LO configuration internal or external LO...

Страница 41: ...2 8 In the name field enter the desired name for this configuration then click on the OK button 9 Repeat this procedure to add more configurations 10 Select Input Channels Custom and review the channe...

Страница 42: ...ed 11 Select Input Extensions and review the measurement hardware input extension parameters The Extensions tab shows which logical instrument is currently active and shows the available hardware exte...

Страница 43: ...ered options is configured at the factory This section shows how to modify the N4392A standard factory configuration 1 In the Keysight 89600 VSA Software interface select Utilities Hardware Discovered...

Страница 44: ...lyzer Getting Started 2 Getting Started 3 Click on the plus button 4 From the Possible Logical Instruments list select Keysight N4392A Optical Modulation Analyzer based on the type of OMA then click o...

Страница 45: ...sight N4391A N4392A Optical Modulation Analyzer Getting Started 45 Getting Started 2 5 In the ADC selection click on the down arrow and select the instrument and input configuration electrical or opti...

Страница 46: ...46 Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 2 Getting Started 6 In the Synthesizer selection click on the down arrow and select the LO configuration internal or external LO...

Страница 47: ...2 7 In the name field enter the desired name for this configuration then click on the OK button 8 Repeat this procedure to add more configurations 9 Select Input Channels Custom and review the channel...

Страница 48: ...ed 10 Select Input Extensions and review the measurement hardware input extension parameters The Extensions tab shows which logical instrument is currently active and shows the available hardware exte...

Страница 49: ...components are pre installed at the factory However this section provides installation instructions if it becomes necessary to reinstall some or all of the software components You can search for updat...

Страница 50: ...n Suite PAS Package Manager is used to select and download software packages for proper operation of the OMA 1 Visit the PAS Package Manager web page at www keysight com find N7700A click on the Techn...

Страница 51: ...Modulation Analyzer Getting Started 51 Getting Started 2 3 Double click on the executable file to run the PAS Package Manager 4 Start the PAS Package Manager as administrator and select the OMA tab to...

Страница 52: ...the default settings The PAS Package Manager will install drivers and software which are required to install the OMA software During the OMA installation itself select your installation type You can p...

Страница 53: ...Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 53 Getting Started 2...

Страница 54: ...54 Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 2 Getting Started...

Страница 55: ...Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 3 Performance Verifica tion N4391A Performance Verification 56 N4392A Performance Verification 56 Returning the Instrument 56...

Страница 56: ...erface opens the dialog for performing N4392A verification Returning the Instrument If the performance verification fails and you cannot correct the problem return the N4391A N4392A to Keysight for re...

Страница 57: ...Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 4 Rack Mount Rack Mounting N4391A Z Series Oscilloscopes 58...

Страница 58: ...ion analyzer for rack mounting a Remove the four feet from the bottom of the optical modulation analyzer b At the front of the optical modulation analyzer remove the covering strips at the left and ri...

Страница 59: ...Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 59 Rack Mount 4 2 Using a Torx T25 screwdriver mount the rails in the rack...

Страница 60: ...ng a cross recess Phillips screwdriver and the screws from the rack mount kit screw part number 0570 1577 screw the flanges at the left and right of the optical modulation analyzer to the rack 4 Mount...

Страница 61: ...Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 61 Rack Mount 4 5 Identify 7U of rack space for instrument Snap on sheet metal fasteners 0590 0804 in the eight locations shown...

Страница 62: ...Modulation Analyzer Getting Started 4 Rack Mount 6 Attach rails to rack Attach rails N2759 03702 as shown using four of the 10 32 flathead fasteners 2510 0283 Ends marked front must be aligned as sho...

Страница 63: ...Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 63 Rack Mount 4 7 Remove handles and bottom feet from the instrument...

Страница 64: ...ysight N4391A N4392A Optical Modulation Analyzer Getting Started 4 Rack Mount 8 Attach rails to instrument Attach rails N2759 03701 to the instrument s top handle holes using four of the screws from S...

Страница 65: ...A Optical Modulation Analyzer Getting Started 65 Rack Mount 4 9 Slide the instrument into the rack as shown The instrument will stop when it reaches the proper depth CAUTION Two people are required to...

Страница 66: ...66 Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 4 Rack Mount 10 Secure the rear of the instrument as shown using two of the 10 32 flathead fasteners 2510 0283...

Страница 67: ...Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 67 Rack Mount 4 11 Attach trim plates Attach trim plates N2759 24101 using four decorative fasteners 0570 1366...

Страница 68: ...68 Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 4 Rack Mount...

Страница 69: ...392A Optical Modulation Analyzer Getting Started 5 Technical Specifica tions Specifications Terms and Conditions N4391A 70 N4391A Specifications 71 Specifications Terms and Conditions N4392A 78 N4392A...

Страница 70: ...environmental changes and aging of components Typical Values Characteristics Characteristics describe the product performance that is usually met but not guaranteed Typical values are based on data f...

Страница 71: ...alignment algorithms 6 Digital demodulation uncertainty Error vector magnitude noise floor 1 8 rms Amplitude error 1 1 rms Phase error 0 9 Quadrature error 0 05 Gain imbalance between I and Q 0 007 d...

Страница 72: ...m Wavelength 1528 nm to 1630 nm External local oscillator input Optical input wavelength range 1528 nm to 1630 nm External local oscillator input power range 0 dBm to 14 dBm Maximum input peak power d...

Страница 73: ...Error Vector Magnitude EVM normalized to the highest error vector within an analysis record of 500 symbols as a function of signal input power The EVM rms level at higher power levels results from the...

Страница 74: ...0 Wavelength range Option 500 1527 6 to 1565 5 nm 196 25 to 191 50 THz 1528 nm to 1630 nm Option 501 1570 0 to 1608 8 nm 190 95 to 186 35 THz Minimum wavelength step 25 GHz 1 pm Tuning time sweep spee...

Страница 75: ...Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 75 Technical Specifications 5 The graph above shows the relative power uncertainty of the N4391A...

Страница 76: ...x 49 cm 19 4 Packaged dimensions DSOX9xx04Z 69 cm x 48 cm x 81 cm Optical receiver 65 cm x 49 cm x 79 cm Weight Product net weight DSOZ xxxA 32 kg 71 lbs DSOZxxxA N4391A system 48 kg 106 lbs Packaged...

Страница 77: ...ut 20 dBm 9 m PMF angled 81000 connector interfaces Coherent receiver optical input LO output 20 dBm max 9 m PMF angled 81000 connector interfaces Laser safety information All laser sources listed abo...

Страница 78: ...environmental changes and aging of components Typical Values Characteristics Characteristics describe the product performance that is usually met but not guaranteed Typical values are based on data f...

Страница 79: ...Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 79 Technical Specifications 5 10 Gbaud symbol rate SinglePolKFPhaseTrack algorithm Q 1E 4 500 symbols per analysis record...

Страница 80: ...Option 100 1527 6 to 1565 5 nm 196 25 to 191 50 THz Optical wavelength range Option 110 1570 01 to 1608 76 nm 190 95 to 186 35 THz Absolute wavelength accuracy with internal local oscillator 3 pm 2 pm...

Страница 81: ...191 50 THz Optical wavelength range Option 110 1570 01 to 1608 76 nm 190 95 to 186 35 THz External local oscillator input power range 3 to 16 dBm Maximum input peak power damage level 20 dBm Basic mod...

Страница 82: ...ents Voltage levels 100 to 240 V AC Net frequency range 50 to 60 Hz Power requirement 375 VA Storage temperature range 40 C to 70 C Operating temperature range 5 C to 35 C Humidity 15 to 80 relative h...

Страница 83: ...rted 83 Technical Specifications 5 Laser safety information All laser sources listed above are classified as Class 1M according to IEC 60825 1 2007 All laser sources comply with 21 CFR 1040 10 except...

Страница 84: ...84 Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 5 Technical Specifications...

Страница 85: ...ht N4391A N4392A Optical Modulation Analyzer Getting Started 6 Regulatory Informa tion Declaration of Conformity 86 Compliance with German Noise Requirements 88 Compliance with Canadian EMC Requiremen...

Страница 86: ...86 Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 6 Regulatory Information Declaration of Conformity...

Страница 87: ...Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 87 Regulatory Information 6...

Страница 88: ...on Noise Declaration for Machines L rmangabe nach der Maschinenl rmverordnung 3 GSGV Deutschland Compliance with Canadian EMC Requirements This ISM device complies with Canadian ICES 001 Cet appareil...

Страница 89: ...10 C Class 1M 14 CSA mark 12 C Tick mark 12 D Declaration of Conformity 11 E Earthing symbol 12 electrostatic discharge 11 I IEC 60825 1 14 K Keysight Infiniium Digital Signal Analyzer 10 L laser rad...

Страница 90: ...90 Keysight N4391A N4392A Optical Modulation Analyzer Getting Started Index...

Страница 91: ...Keysight N4391A N4392A Optical Modulation Analyzer Getting Started 91...

Страница 92: ...This information is subject to change without notice Keysight Technologies 2014 Edition 2 0 October 2014 www keysight com...

Отзывы: