12
Keysight M9502A/M9505A AXIe Chassis User Guide
Introduction
Power-Up and Power-Down
Power-Up and Power-Down
Circuit Breaker
The chassis circuit breaker is a toggle switch, marked OFF (O) when open and ON
(I) when closed:
ON/STANDBY Switch
The chassis’ button on the front of the chassis is the
ON/STANDBY
switch, lit when
the chassis is ON:
Power Modes
The chassis has three power modes:
OFF
With the power cord removed or the circuit breaker in the open position,
the chassis is
OFF
.
STANDBY
With the power cord connected, the circuit breaker closed, and the
front panel switch in the standby (not depressed) position, the chassis is in
STANDBY
mode. Although no power is supplied to the ESM and installed modules
when in Standby, the chassis is energized and consumes power. Fans may
operate.
ON
With the power cord attached, circuit breaker closed, and the front panel
switch in the
ON
(depressed) position, the chassis is
ON
. Power is supplied to the
ESM and installed modules. Fans will operate as dictated by chassis thermal
load.
Circuit Breaker Open (OFF)
Circuit Breaker Closed (ON)
STANDBY
(off if power is disconnected
or breaker is open)
ON
Содержание M9502A
Страница 1: ...Keysight M9502A 2 Slot and M9505A 5 Slot AXIe Chassis User Guide...
Страница 2: ......
Страница 30: ...20 Keysight M9502A M9505A AXIe Chassis User Guide Introduction Product Warranty...
Страница 68: ...58 Keysight M9502A M9505A AXIe Chassis User Guide Navigating the Web Interface Chassis Health Page...
Страница 74: ...64 Keysight M9502A M9505A AXIe Chassis User Guide Using the Soft Front Panel SFP Screens...
Страница 82: ...72 Keysight M9502A M9505A AXIe Chassis User Guide Features and Functions Shelf Management Functions...
Страница 118: ...108 Keysight M9502A M9505A AXIe Chassis User Guide For Module Developers Chassis Backplane Connections...
Страница 138: ...128 Keysight M9502A M9505A AXIe Chassis User Guide Glossary...
Страница 141: ......