74
Keysight InfiniiVision 1000 X-Series Oscilloscopes User's Guide
2
Quick Reference
CAN Decode/Trigger
On DSOX1000-Series oscilloscopes, the CAN serial decode and triggering option
can be enabled with the AUTO license.
When interpreting the decode waveforms, see the
Mode
softkey built-in help.
Table 24
Serial Bus Decode/Trigger Features
Feature
Front Panel Key/Softkey Location (see built-in help for more information)
Serial bus select,
enable/disable
[Bus] > Select
,
Entry knob to select
Serial Bus
, push
Select
softkey or Entry knob to enable or
disable
Serial bus mode
[Bus] > Mode
, Entry
knob
(CAN
*
, I2C, LIN
*
, SPI
*
, UART/RS232)
The built-in help for the
Mode
softkey describes the decode waveforms.
Serial bus trigger
[Trigger] > Trigger Type, Serial 1
*
CAN, LIN, and SPI are available on DSOX1000-Series models only
Table 25
CAN Decode/Trigger Features
Feature
Front Panel Key/Softkey Location (see built-in help for more information)
CAN signal setup
After selecting the Serial Bus and the CAN serial bus mode, press
[Bus] > Signals >
to open the CAN
Signals menu. In this menu, you can select the oscilloscope source channel probing the signal and
the appropriate threshold voltage to use when decoding/triggering the signal, as well as other signal
options.
CAN baud rate
[Bus] > Signals > Baud
, Entry
knob
CAN sample point
[Bus] > Signals > Sample Point
, Entry
knob
CAN signal
type/polarity
[Bus] > Signals > Signal
,
Entry knob (Rx, Tx, CAN_H, CAN_L, Differential (L-H), Differential
(H-L))
CAN counters
[Bus] > Reset CAN Counters
Counters run even when the oscilloscope is stopped (not acquiring data).
When an overflow condition occurs, the counter displays
OVERFLOW
.