2 Programming the Test Set
Common Commands
will also generate status bits.
Initial S/W Revision
Prior to A.02.00
Standard Event Status Enable
Selects the desired bits from the standard event status enable register. This register monitors I/O errors
and synchronization conditions such as operation complete, request control, query error, device
dependent error, status execution error, command error, and power on. The selected bits are OR’d to
become a summary bit (bit 5) in the byte register which can be queried.
The query returns the state of the standard event status enable register.
Key Path
No equivalent key. Related key System, Show Errors, Clear Error Queue
Remote Command
*ESE <integer>
*ESE?
Example
*ESE 36 Enables the Standard Event Status Register to monitor query and command errors (bits 2
and 5).
*ESE? Returns a 36 indicating that the query and command status bits are enabled.
Notes
For related commands, see the STATus subsystem and SYSTem:ERRor[:NEXT]? commands.
Preset
255
State Saved
Not saved in state.
Min
0
Max
255
Status Bits/OPC
dependencies
Event Enable Register of the Standard Event Status Register.
Initial S/W Revision
Prior to A.02.00
Standard Event Status Register Query
Queries and clears the standard event status event register. (This is a destructive read.) The value
returned is a hexadecimal number that reflects the current state (0/1) of all the bits in the register.
Remote Command
*ESR?
Example
*ESR? Returns a 1 if there is either a query or command error, otherwise it returns a zero.
Notes
For related commands, see the
STATus
subsystem commands.
Preset
0
Min
0
Max
255
Status Bits/OPC
dependencies
Standard Event Status Register (bits 0 – 7).
Initial S/W Revision
Prior to A.02.00
88
Sequence Analyzer User's & Programmer's Reference
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...