![Keysight E6650A EXF Скачать руководство пользователя страница 622](http://html1.mh-extra.com/html/keysight/e6650a-exf/e6650a-exf_user-programming-manual_1961647622.webp)
6 List Sequence Measurements
Source
sequence will automatically apply header settings of the selected waveform in that step.
Initial S/W Revision
A.05.00
Continue Previous
Sets the current step to continue with playback of the waveform from the previous step. When continuing
the previous waveform, the ARB playback will not pause while the source retunes to the new frequency or
amplitude that may be defined for the new step.
Key Path
Source, List Sequencer, List Sequencer Setup, Waveform
Example
:SOUR:LIST:STEP2:SET:WAV “Cont”
Notes
SCPI is supported after A.09.40
Initial S/W Revision
A.05.00
Off
Disable RF outpu of the current step.
Key Path
Source, List Sequencer, List Sequencer Setup, Waveform
Example
:SOUR:LIST:STEP2:SET:WAV “Off”
Notes
SCPI is supported after A.09.40
Initial S/W Revision
A.05.00
Segments on Hard Disk
Allows you access to the sub-menus for loading waveform segments from the hard disk into ARB memory.
The default directory is: D: varb.
Pressing this key changes the current view to the Waveform Management View.
Key Path
Source, Modulation Setup, ARB, Select Waveform
Initial S/W Revision
A.05.00
Load Segment To ARB Memory
Allows you to load the selected file into ARB memory. On the front panel you select the file for loading to
the ARB memory by highlighting the desired file in the list. Using the SCPI command, you specify the file
name on the HDD.
“NVWFM” (none-volatile storage) MSUS (Mass Storage Unit Specifier) is supported in the memory
subsystem because the ARB memory cannot be accessed directly. Therefore, files must be downloaded to
the instrument hard disk and then loaded into the ARB memory. “NVWFM” MSUS will be mapped to the
622
Sequence Analyzer User's & Programmer's Reference
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...