6 List Sequence Measurements
Source
ALC Hold
Allows you to specify which marker is routed for use within the ALC hold function. The ALC hold marker
function holds the ALC circuitry at the average value of the sample points set by the marker.
The ALC hold function operates during the low periods of the marker signal. The marker polarity
determines when the marker signal is high. For positive polarity, this is during the marker points. For a
negative polarity, this is when there are no maker points.
Key Path
Source, Modulation Setup, ARB, Marker Utilities, Marker Routing
Remote Command
:SOURce:RADio:ARB:MDEStination:ALCHold NONE|M1|M2|M3|M4
:SOURce:RADio:ARB:MDEStination:ALCHold?
Example
:SOUR:RAD:ARB:MDES:ALCH NONE
Dependencies
When a new waveform is selected for playback the settings contained within the associated
waveform header file are applied to the ARB. The ALC hold setting is one of the values stored within
the header file. If the newly selected waveform file has an associated header file, the ALC hold setting
is updated with the value from the header file. The ALC hold setting will remain unchanged if the
newly selected waveform does not have an associated header file.
Range
None | M1 | M2 | M3 | M4
Initial S/W Revision
A.05.00
None
Sets no marker to be used for the ALC hold function, essentially turning the ALC hold function off.
Key Path
Source, Modulation Setup, ARB, Marker Utilities, Marker Routing, ALC Hold
Example
:SOUR:RAD:ARB:MDES:PULS NONE
Initial S/W Revision
A.05.00
Marker 1
Sets marker 1 to be used for the ALC hold function.
Key Path
Source, Modulation Setup, ARB, Marker Utilities, Marker Routing, ALC Hold
Example
:SOUR:RAD:ARB:MDES:PULS M1
Initial S/W Revision
A.05.00
Marker 2
Sets marker 2 to be used for the ALC hold function.
Key Path
Source, Modulation Setup, ARB, Marker Utilities, Marker Routing, ALC Hold
Example
:SOUR:RAD:ARB:MDES:PULS M2
Initial S/W Revision
A.05.00
590
Sequence Analyzer User's & Programmer's Reference
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...