![Keysight E6650A EXF Скачать руководство пользователя страница 583](http://html1.mh-extra.com/html/keysight/e6650a-exf/e6650a-exf_user-programming-manual_1961647583.webp)
6 List Sequence Measurements
Source
Waveform slot number <int> is positive. If you attmpt to input a slot number less than or equals 0, an
error is generated.
Dependencies
This key is only available if the currently selected slot is in the trial state.
Initial S/W Revision
A.05.00
Lock Waveform in Slot
If the selected slot is in the trial state or the lock required state, the waveform that occupies the slot is
locked and permanently licensed.
Key Path
Source, Modulation Setup, ARB, Waveform Utilities, Multi-Pack Licenses
Remote Command
:SYSTem:LKEY:WAVeform:LOCK <int>
or
:SYSTem:LICense[:FPACk]:WAVeform:LOCK <int>
Example
SYST:LKEY:WAV:LOCK 1
or
SYST:LIC:WAV:LOCK 1
Notes
The second SCPI :SYSTem:LICense[:FPACk]:WAVeform:LOCK is provided to be consistent with the
style of Keysight signal sources. You can use either one of them.
Waveform slot number <int> is positive. If you attmpt to input a slot number less than or equals 0, an
error is generated.
Dependencies
This key is only available if the currently selected slot is in the trial state or the lock required state.
Initial S/W Revision
A.05.00
Slot Status Query (Remote Command Only)
Returns the status of the specified slot.
Remote Command
:SYSTem:LKEY:WAVeform:STATus? <int>
or
:SYSTem:LICense[:FPACk]:WAVeform:STATus? <int>
Example
:SYST:LKEY:WAV:STAT? 1
<"Locked"
or
:SYST:LIC:WAV:STAT? 1
<"Locked"
Notes
The second SCPI :SYSTem:LICense[:FPACk]:WAVeform:STATus is provided to be consistent with the
style of Keysight signal sources. You can use either one of them.
Waveform slot number <int> is positive. If you attmpt to input a slot number less than or equals 0, an
Sequence Analyzer User's & Programmer's Reference
583
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...