![Keysight E6650A EXF Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/keysight/e6650a-exf/e6650a-exf_user-programming-manual_1961647028.webp)
1 About the Test Set
Window Control Keys
Window Control Keys
Multi-Window
The Multi Window front-panel key will toggle you back and forth between the Normal View and the last
Multi Window View (Zone Span, Trace Zoom or Spectrogram) that you were in, when using the Swept SA
measurement of the Spectrum Analyzer Mode. It remembers which View you were in through a Preset.
This “previous view” is set to Zone Span on a Restore Mode Defaults.
Key Path
Front-panel key
Initial S/W Revision
Prior to A.02.00
Zoom
Zoom is a toggle function. Pressing this key once increases the size of the selected window. Pressing the
key again returns the window to the original size.
When Zoom is on for a window, that window will get the entire primary display area. The zoomed window,
since it is the selected window, is outlined in green.
Zoom is local to each Measurement. Each Measurement remembers its Zoom state. The Zoom state of
each Measurement is part of the Mode’s state.
Data acquisition and processing for the other windows continues while a window is zoomed, as does all
SCPI communication with the other windows.
Remote Command
:DISPlay:WINDow:FORMat:ZOOM
Remote Command
:DISPlay:WINDow:FORMat:TILE
Example
:DISP:WIND:FORM:ZOOM sets zoomed
:DISP:WIND:FORM:TILE sets un-zoomed
Preset
TILE
Initial S/W Revision
Prior to A.02.00
Next Window
Selects the next window of the current view.When the Next Window key is pressed, the next window in the
order of precedencebecomes selected. If the selected window was zoomed, the next window will also be
zoomed.
The window numbers are as follows. Note that these numbers also determine the order of precedence
(that is, Next Window goes from 1 to 2, then 2 to 3, etc.):
28
Sequence Analyzer User's & Programmer's Reference
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...