5 System Functions
System
Key Path
System, I/O Config, IDN Response
Example
:SYST:IDN:CONF USER
Initial S/W Revision
A.06.00
SYSTem:IDN Response setting (Remote command)
This SCPI command is used to set or clear the User SYSTem:IDN response.
Remote Command
:SYSTem:IDN <string>
:SYSTem:IDN?
Notes
•
The format of the <string> must be four fields each separated by a comma, example:
:SYST:IDN “XYZ Corp,Model 12,012345,A.01.01”
•
The four fields are <manufacturer>, <model number>, <serial number>, <firmware revision>.
Thus, the text within a field cannot contain a comma.
•
This affects the response given in all Modes of the Analyzer, unless the current Mode has also
specified a custom response, in which case the current Mode’s custom IDN response takes
precedence over the System’s, but only while that Mode is the current Mode..
•
It survives shutdown and restart of the software and therefore survives a power cycle
•
Null string as parameter restores the Factory setting, example:
:SYST:IDN ""
Preset
This is unaffected by Preset but is set to the original factory setting on a “Restore System Defaults-
>Misc”
Initial S/W Revision
A.06.00
Agilent
Starting with software version x.14.50, the *IDN? response in the Factory configuration will indicate the
Manufacturer as Keysight Technologies. If your test software is expecting the response to indicate Agilent
Technologies you can conveniently configure the response with this menu selection key or SCPI command.
For example:
“Agilent Technologies,N9020A,MY00012345,A.05.01”
Key Path
System, I/O Config, IDN Response
Example
:SYST:IDN:CONF AGIL
Initial S/W Revision
x.14.50
Restore Defaults
Provides incremental initialization of the system setting groups along with supporting a comprehensive
reset of the entire instrument back to a factory default state. The menu selections are the groups of system
190
Sequence Analyzer User's & Programmer's Reference
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...