Table 3-2
Counter Configuration using CONFigure and MEASure
Parameter
CONFigure/MEASure Setting
Low-Level Command/Subsystem
Input
range, low-pass filtering, coupling,
impedance and noise rejection are
unchanged from previous or their
power-on settings.
INPut{[1]:RANGe
INPut[1]:FILTer
INPut[1]:COUPling
INPut[1]:IMPedance
INPut[1]:NREJect
Trigger source
IMMediate
TRIGger:SOURce
Trigger slope
NEGative
TRIGger:SLOPe
Trigger delay
0.0 seconds
TRIGger:DELay
Trigger count
1 trigger
TRIGger:COUNt
Sample count
1 sample
SAMPle:COUNt
GATE Source
Based on measurement function
specified by the CONFigure or
MEASure command.
SENSe:FREQuency:GATE:SOURce
External Gate Source
Gate In/Out BNC
OUTPut:STATe
Math
Graphics
Disabled, including the individual
calculate functions. Other
parameters are unchanged.
CALCulate1 subsystem
CALCulate2 subsystem
Auto-level Frequency
Unchanged
SYSTem:ALEVel:FREQuency
Measurement Timeout
Unchanged
SYSTem:TIMeout
Reference oscillator
Unchanged from previous settings.
SENSe:ROSCillator:SOURce
SENSe:ROSCillator:SOURce:AUTO
SENSe:ROSCillator:EXTernal:FREQu
ency
Reading Format
Data Storage
Instrument Status
Unchanged from previous settings.
Unchanged from previous settings.
Unchanged from previous settings.
FORMat Subsystem
DATA Subsystem
STATus Subsystem
Содержание 53210A
Страница 1: ...Keysight 53210A 350 MHz RF Counter User s Guide ...
Страница 12: ...12 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 18: ...18 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 22: ...22 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 24: ...1 Preparation for Use 24 Keysight 53210A User s Guide Figure 1 1 The 53210A Universal Frequency Counter Timer ...
Страница 48: ...1 Preparation for Use 48 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 122: ...4 53210A Input Signal Conditioning 122 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 222: ...8 Instrument Status 222 Keysight 53210A User s Guide Figure 8 1 The 53210A Status System Instrument Locked Global Error ...
Страница 228: ...8 Instrument Status 228 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 240: ...A 53210A Error Messages 240 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 246: ...246 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...