![Keysight 53210A Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/keysight/53210a/53210a_user-manual_1961097025.webp)
Preparation for Use
1
Keysight 53210A User’s Guide
25
Front and Rear Panel Overview
shows the front and rear panels of the Keysight 53210A 350 MHz RF
Counter.
Front Panel
The shaded areas of the front panel represent keys that perform similar functions.
These areas are briefly described below.
A. Measure Keys
- display soft key menus from which the measurement function
is selected. Auto Scale senses the input signal (greater than 100 Hz) on input
channel 1, 2, or 3 and automatically sets the range and input threshold required to
make the selected measurement. Counter measurements are covered in
B. View Keys
- select how measurement data is displayed on the front panel.
Display configuration is covered later in this chapter. Graphics, math, and data
logging are covered in
C. System Keys
- provide instrument-wide configuration which includes setting
the counter preset state and access to utility functions and to the counter’s
built-in help system. For measurement configuration involving numeric entry,
Shift changes the key definitions to the numbers at the lower left of the keys.
D. Channel Keys
- select the input channel and displays the soft key menu used
to configure the input signal path. Note that
includes Channel 3 Option
106 / 115. Signal path configuration is covered in
.
E. Gate and Trigger Keys
- select the gating and triggering soft key menus used
to control the measurement. Gating and triggering are covered in
F. Soft Keys
- are the menus from which the counter is configured. The menus
and soft keys themselves are defined by the “functional” keys described above.
G. Power/Standby Button
- switches the instrument between ‘on’ and ‘off’, or
between ‘on’ and ‘standby’.
Содержание 53210A
Страница 1: ...Keysight 53210A 350 MHz RF Counter User s Guide ...
Страница 12: ...12 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 18: ...18 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 22: ...22 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 24: ...1 Preparation for Use 24 Keysight 53210A User s Guide Figure 1 1 The 53210A Universal Frequency Counter Timer ...
Страница 48: ...1 Preparation for Use 48 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 122: ...4 53210A Input Signal Conditioning 122 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 222: ...8 Instrument Status 222 Keysight 53210A User s Guide Figure 8 1 The 53210A Status System Instrument Locked Global Error ...
Страница 228: ...8 Instrument Status 228 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 240: ...A 53210A Error Messages 240 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 246: ...246 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...