Keysight 2050 Series Скачать руководство пользователя страница 1

Keysight 2050/ 60 X- Series 
Wide Dynamic Range Power 
Sensors

Wide dynamic range power sensors for 
any modulated signals

User’s Guide

Содержание 2050 Series

Страница 1: ...Keysight 2050 60 X Series Wide Dynamic Range Power Sensors Wide dynamic range power sensors for any modulated signals User s Guide...

Страница 2: ...ghts customarily provided to the public to use modify reproduce release per form display or disclose commercial computer software or commercial com puter software documentation No additional governmen...

Страница 3: ...s complies with the following Electromagnetic Compatibility EMC compliances IEC 61326 1 EN 61326 1 Canada ICES NMB 001 Australia New Zealand AS NZS CISPR11 Environmental condition Requirement Temperat...

Страница 4: ...dustrial Scientific and Medical Group 1 Class A product This symbol indicates the time period during which no hazardous or toxic substance elements are expected to leak or deteriorate during normal us...

Страница 5: ...complies with the WEEE Directive marking requirement This affixed product label indicates that you must not discard this electrical or electronic product in domestic household waste Product category W...

Страница 6: ...or sales and technical support refer to the support links on the following Keysight websites www keysight com find widedynamicsensor product specific information and support software and documentation...

Страница 7: ...Mount the L2065XT 66XT 67XT 39 Mounting dimensions 39 Mounting procedure 40 LED Indicator Sequence During Power Up for the USB Sensor 42 Other LED indicators 42 LED Indicator Sequences for the LAN Sen...

Страница 8: ...60 X Series Web Interface 69 Launching the web interface 69 Navigation Bar 69 Displaying the Instrument control page 70 3 Characteristics and Specifications A Appendix Simplified Measurement Path 82 T...

Страница 9: ...Set automatic LAN settings on the PC 31 Figure 1 15 Auto locate a LAN instrument in Keysight Connection Expert 31 Figure 1 16 Modify and renew LAN configuration settings 32 Figure 1 17 Set manual LAN...

Страница 10: ...gure 2 21 Instrument setup advanced settings pane 57 Figure 2 22 Power meter settings in the Average only mode 58 Figure 2 23 Power meter settings in the Normal mode 60 Figure 2 24 Instrument Setup ta...

Страница 11: ...sensor 42 Table 1 2 Other LED indicators for the LAN sensor 44 Table 2 1 Power meter settings in the Average only mode description 59 Table 2 2 Power meter settings in Normal mode description 61 Table...

Страница 12: ...12 Keysight 2050 60 X Series User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Страница 13: ...ation 22 Connect the USB sensor 22 Connect the LAN sensor 24 LED Indicator Sequence During Power Up for the USB Sensor 42 LED Indicator Sequence During Power Up for the USB Sensor 42 Other LED indicat...

Страница 14: ...r sensor 10 MHz to 40 GHz U2065XA USB peak and average power sensor 10 MHz to 50 GHz U2065XA option 053 peak and average power sensor 10 MHz to 53 GHz U2066XA USB peak and average power sensor 10 MHz...

Страница 15: ...or is capable of long distance remote monitoring of up to 100 meters via the Power over Ethernet PoE LAN connectivity The PoE connectivity is compliant to the IEEE 3 W 802 3af or 802 3at Type 1 standa...

Страница 16: ...1 USB sensor LED indicator Indicates the USB sensor state Refer to LED Indicator Sequence During Power Up for the USB Sensor on page 42 for more information RF input port for RF microwave signals USB...

Страница 17: ...n when the operating speed is 10 Mbps or during line isolation Amber blinking Link activity indicator Blinks when a valid link activity is detected LED indicators Indicate the LAN sensor state Refer t...

Страница 18: ...n average power sensor and traditionally this type of measurement means that an instrument will output a numeric result at some rate determined by the instrument In AVERAGE mode the sensor enables a c...

Страница 19: ...esistor also changes the response level V W of the diode detector and its video bandwidth Changing the load capacitance will affect the bandwidth but not the response level Used together these control...

Страница 20: ...there is any mechanical damage notify the nearest Keysight Sales and Service Office Keep the damaged shipping materials if any for inspection by the carrier and a Keysight representative Standard ship...

Страница 21: ...50 60 X Series User s Guide 21 LAN power sensor LAN power sensor Trigger cable BNC male to SMB female 50 W 1 5 m Quantity 2 Certificate of calibration Certificate of calibration Shielded LAN cable 5 f...

Страница 22: ...nect the USB sensor 1 Connect the power sensor to the PC The sensor driver is detected and installed automatically Figure 1 4 Connect the U2053XA 63XA sensor to the PC 2 Go to Start All Programs IO Co...

Страница 23: ...s connected 4 When the sensor is connected go to Chapter 2 Using the 2050 60 X Series with the Keysight BenchVue to launch the BenchVue Power Meter application or proceed to operate the sensor via rem...

Страница 24: ...he LAN sensor to obtain an IP address The LAN sensor will then try to obtain the LAN configuration using AutoIP if enabled otherwise the LAN sensor will try to use the static IP set in the LAN sensor...

Страница 25: ...n Properties and set the following properties Figure 1 7 Set automatic LAN settings on the PC 3 Go to Start All Programs IO Control to launch Keysight Connection Expert application 4 Select Add LAN in...

Страница 26: ...trument in Keysight Connection Expert via host name 6 Select Allow IDN Query and click Test This VISA Address to verify the LAN sensor is connected Once verified click Accept 7 Alternatively click Sta...

Страница 27: ...nt in Keysight Connection Expert via Dynamic IP 8 Click Interactive IO to verify the LAN sensor is connected 9 When the LAN sensor is connected go to Chapter 2 Using the 2050 60 X Series with the Keys...

Страница 28: ...nment Figure 1 10 Connect the LAN sensor via Auto IP 1 Set up the connection as shown above 2 On your PC set the LAN settings to the automatic configuration Go to Start Control Panel Network and Inter...

Страница 29: ...truments to auto locate the sensor as shown in the figure below Figure 1 12 Auto locate a LAN instrument in Keysight Connection Expert 4 Click Interactive IO to verify the LAN sensor is connected 5 Wh...

Страница 30: ...h the instrument using the same IP address every time it is turned on Figure 1 13 Connect the LAN sensor via Static IP 1 Set up the connection as shown above 2 On your PC set the LAN settings to the a...

Страница 31: ...ic LAN settings on the PC 3 Go to Start All Programs IO Control to launch Keysight Connection Expert application Click Start a Scan for connected instruments to auto locate the sensor as shown in the...

Страница 32: ...N sensor web based interface see Using the Instrument Web Browser on page 35 On the Configuring your L20xxXA Power Sensor page set the DHCP and Auto IP buttons to OFF Click Save to save the new settin...

Страница 33: ...ght Connection Expert application Click Start a Scan for connected instruments to auto locate the sensor as shown in Figure 1 18 NOTE For the new network settings to become effective you must first po...

Страница 34: ...gramming NOTE Alternatively you can locate the LAN sensor by entering its default static IP address 192 168 0 10 in the Add a LAN device Add LAN instrument window NOTE To revert to the Dynamic IP mode...

Страница 35: ...can also be used for interactive IO familiarization with instrument capabilities determining changing instrument configuration 1 On the Keysight Connection Expert click Web UI to launch the LAN sensor...

Страница 36: ...d 36 Keysight 2050 60 X Series User s Guide Figure 1 20 LAN sensor web based interface Welcome page 2 Click View Modify Configuration to access the LAN configuration settings Figure 1 21 View and modi...

Страница 37: ...2050 60 X Series User s Guide 37 Figure 1 22 View and modify LAN configuration settings 3 Click Modify Configuration to edit the LAN configuration settings Figure 1 23 Modify configuration 4 Enter the...

Страница 38: ...5 On this page you can configure and renew the LAN settings as well as power cycle the LAN sensor or reset the LAN settings Figure 1 25 Modify and renew LAN configuration settings NOTE If you have ch...

Страница 39: ...es Programming Guide for details Mount the L2065XT 66XT 67XT The L2065XT 66XT 67XT is strongly recommended to be mounted on a cooling plate for more effective heat dissipation when used in a TVAC cham...

Страница 40: ...de Mounting procedure Clean the surface thoroughly with isopropyl alchohol and let it dry Stick the silver layer onto the surface The pink layer is facing outward Install the thermal interface materia...

Страница 41: ...Getting Started 1 Keysight 2050 60 X Series User s Guide 41 Place the sensor with brackets on the cooling plate Align the screws to the threaded holes and tighten the screws...

Страница 42: ...s recommended to return the 2050 60 X Series to Keysight if this condition persists after power cycle Green Amber Red Red blinking Table 1 1 Other LED indicators for the USB sensor Secure erase flash...

Страница 43: ...ery to read the error message It is recommended to return the LAN sensor to Keysight if this condition persists after power cycle Green Amber Red Red blinking Power up LAN reset Normal operation Devic...

Страница 44: ...file and help file for installing the Firmware Upgrade Utility application in order to upgrade the 2050 60 X Series Table 1 2 Other LED indicators for the LAN sensor Secure erase flash formatting or f...

Страница 45: ...view 51 Quick overview of the BenchVue Power Meter 55 57 Power meter settings in the Normal mode 60 Instrument Setup tab 63 Overview of Multiple Power Sensor Operation 65 Single bench operation 65 Mu...

Страница 46: ...the Instrument panel to start controlling the power sensor b If the sensor is found in the Keysight Connection Expert but is not shown in the BenchVue Instrument panel select the refresh icon to refre...

Страница 47: ...tor as follows Amplitude 0 dBm Frequency 1 GHz Modulation Disabled 2 Turn on the RF output of the signal generator Launch the BenchVue Power Meter application refer to page 46 By default the power met...

Страница 48: ...sition of measurements in the Run mode b Indicates the measurement status c Change the title at the top of the display view Reset the displayed Minimum Maximum measured values d Summary of alert limit...

Страница 49: ...igure 2 8 Data preview bar a Data preview bar b Indicates the channel name measurement number measurement type c Tools palette to provide control for the datalog chart refer to the BenchVue Power Mete...

Страница 50: ...2 General Operating Information 50 Keysight 2050 60 X Series User s Guide 7 Place a marker or up to five markers on the chart by clicking to obtain the reading Figure 2 9 Placing a marker on the chart...

Страница 51: ...BenchVue Power Meter application refer to page 46 3 Create a Trace display view by clicking Figure 2 10 Creating a trace 4 Perform calibration and zeroing for an accurate measurement result Figure 2...

Страница 52: ...set the trace scales to configure the pulse on the trace display Figure 2 13 Setting the trace scales 7 To enable gates on the trace click at the Tools Palette NOTE For power measurement below 50 dBm...

Страница 53: ...your gate parameters you can set up the gates via the Instrument Setup tab and enter a starting point and length in seconds for each of the four gate controls Figure 2 15 Setting the gates through In...

Страница 54: ...de 8 View the power measurement results of the pulse at the Pulse Analysis tab under Information Panel Figure 2 16 Viewing the power measurement results of the pulse You can select additional pulse an...

Страница 55: ...ck to create a new MultiList display view Click to assign a measurement to the selected display view Click to start or stop all assigned measurements on all display views simultaneously For more infor...

Страница 56: ...h a state file extension Figure 2 20 Save load the instrument state c Access advanced settings such as corrections frequency dependent offset gamma and S parameter alert limits recorder output trace p...

Страница 57: ...General Operating Information 2 Keysight 2050 60 X Series User s Guide 57 Figure 2 21 Instrument setup advanced settings pane...

Страница 58: ...s User s Guide Power meter settings in the Average only mode Figure 2 22 Power meter settings in the Average only mode Add a display view Assign a measurement to the selected view Start Stop all acqui...

Страница 59: ...o zero the 2050 60 X Series internally or externally Internal zeroing can be performed with or without the RF microwave signal present while external zeroing must be performed without any RF microwave...

Страница 60: ...uide Power meter settings in the Normal mode Figure 2 23 Power meter settings in the Normal mode Common Normal mode power measurement settings Common Normal mode Trace view settings Add a display view...

Страница 61: ...logarithmic dBm or linear Watt measurement unit Set the measurement offset factor The 2050 60 X Series corrects every measurement by this factor to compensate for the gain loss Enable the relative mod...

Страница 62: ...ing digital signal processing techniques to ensure accurate power measurement within the specified band When the video bandwidth is set to Off it removes all digital signal conditioning This provides...

Страница 63: ...ion 2 Keysight 2050 60 X Series User s Guide 63 Instrument Setup tab This tab provides you an option to configure additional instrument settings for your measurements as described in Table 2 3 Figure...

Страница 64: ...nt offset FDO which compensates for frequency related changes in the response of your test system The BenchVue Power Meter application can store 10 FDO tables with 512 frequency points each Set the ga...

Страница 65: ...o operate multiple sensors using the BenchVue Power Meter application Single bench operation Multiple Digital Meter display views Select the instruments to use at Instrument Setup Additional Instrumen...

Страница 66: ...0 X Series User s Guide Multi list display view Select the instruments to use at Instrument Setup Additional Instruments Add a Multilist display view by clicking and selecting the measurement sources...

Страница 67: ...ries User s Guide 67 Single Trace display view with multiple traces Select the instruments to use at Instrument Setup Additional Instruments Add a Trace display view by clicking and selecting the trac...

Страница 68: ...es User s Guide Multiple bench operation Figure 2 28 Multiple bench display example Sensor number Set the sensor bench view layout Corresponds with respective sensor number Double click each connected...

Страница 69: ...gate to Connections exact navigation depends on your browser and then select LAN Settings 3 From the LAN Settings dialog select activate bypass proxy server for local addresses exact terminology depen...

Страница 70: ...sors Figure 2 31 Password Panel Welcome page Displays the detailed information Instrument Control Allows you to control the configuration of sensor setting through different HTML input types such as b...

Страница 71: ...n 2 Keysight 2050 60 X Series User s Guide 71 4 Using various available HTML buttons text input radio buttons you can control configuration of sensor settings in the instrument control panel Figure 2...

Страница 72: ...ude AUTO to the measurement signal Deselect the check box so that the measurement signal remains unchanged By default this field is disabled The corresponding SCPI command is CALCulate 1 2 3 4 RELativ...

Страница 73: ...z to 1000 GHz By default the frequency is set to 50 MHz The corresponding SCPI command is SENSe 1 FREQuency CW FIXed numeric_value 3 Chan Offset Sets the channel offset for 2050 60 X Series sensors Se...

Страница 74: ...ct the unit from the drop down and enter the aperture time value The range of aperture time allowed for 2050 60 X Series sensors is 20us to 200ms for 300 MHz For 300 MHz the minimum aperture size is 5...

Страница 75: ...xternal or internal zeroing mode The corresponding SCPI command is CAL ZERO TYPE INT EXT Figure 2 37 Calibration Panel System Panel The System panel allows you to select one of the following options 1...

Страница 76: ...System panel Figure 2 39 System Panel Presets and Reset Digital Meter Display Panel In Digital Meter Display panel the following buttons are used to trigger the measurement 1 Start 2 Stop 3 Single Mea...

Страница 77: ...Web Interface is supported and can be best viewed with the latest version of Google Chrome Opera and Microsoft Edge web browsers Figure 2 41 Footer System Error There is a System Error bar on the top...

Страница 78: ...2 General Operating Information 78 Keysight 2050 60 X Series User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Страница 79: ...namic Range Power Sensors User s Guide 3 Characteristics and Specifications NOTE For the characteristics and specifications of the 2050 60 X Series refer to the datasheet at http literature cdn keysig...

Страница 80: ...3 Characteristics and Specifications 80 Keysight 2050 60 X Series User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Страница 81: ...60 X Series Wide Dynamic Range Power Sensors User s Guide A Appendix Simplified Measurement Path 82 Typical Averaged Readings 83 Bandwidth Filter Shapes 85 Measurement Gates 86 Limit Checking Applicat...

Страница 82: ...A Appendix 82 Keysight 2050 60 X Series User s Guide Simplified Measurement Path FDO Channel offset Measurement highway Measurement 1 Measurement 2 Measurement 3 Measurement 4 Gamma S parameter...

Страница 83: ...dBm Dynamic range Number of averages Resolution setting 1 2 3 4 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 58 dBm 60 dBm 65 100 100 100 26 100 100 100 10 100 100 100 62 dBm 52 dBm...

Страница 84: ...Maximum power The four resolution levels represent 1 0 1 0 01 0 001 dB respectively if the measurement suffix is dBm or dB 1 2 3 or 4 significant digits respectively if the measurement suffix is W or...

Страница 85: ...A Keysight 2050 60 X Series User s Guide 85 Bandwidth Filter Shapes 1 1 When the 2050 60 X Series frequency is set to 300 MHz Amplitude 0 3 dB Bandwidth setting Low Med High Off Frequency 5 MHz 1 5 MH...

Страница 86: ...ecified by the gate are used for the measurements in that gate A system of up to four independent gates is provided Below is an example of a 4 gate setup to perform the following measurements simultan...

Страница 87: ...side these limits as shown below Table A 1 Range of values for limits Unit Maximum Minimum Default maximum Default minimum dB 200 dB 180 dB 60 dB 120 dB dBm 230 dBm 150 dBm 90 dBm 90 dBm 10 0 Z 100 0...

Страница 88: ...A Appendix 88 Keysight 2050 60 X Series User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Страница 89: ...bject to change without notice Always refer to the English version at the Keysight Web site for the latest revision Keysight Technologies 2015 2021 Edition 5 August 20 2021 Printed in Malaysia U2063 9...

Отзывы: