1
Keysight ZA0060A Quick Start Guide
30
7
Once the test is complete, you can view the results at the Step Settings tab for
each test step. For those who have set up the 'Simple CSV Listener' plug-ins,
find your results at
C:\Program Files\Keysight\Tap8\Results
and open it in
Microsoft Excel.
Test Steps and Description
Zigbee Network Configuration
This test step functions to configure network protocol according to the step settings below.
Step Settings
– Channel: Select the Zigbee channel for Packet Error Rate (PER) test from Channel 11 to 26, subject to
the channel set by the DUT for transmission (MHz).
– PAN ID (Hex/Decimal): Enter the unique PAN ID of the Zigbee network to allow communication
between the coordinator and router. You can use the PAN ID created by the coordinator or the known
PAN ID embedded.
– Enable Secure Network: Select this check box for DUT with link key code enabled (security feature of
Zigbee device). You will need to enter the link key code, otherwise the tester will not be able to
establish connection with the DUT.
– Link Key: Choose 'Enable Secure Network' to display this key. You will need to enter the specific link
key of the DUT to establish a connection.
The PAN ID of the system needs to match the PAN ID of the DUT, or the PAN ID of the DUT needs to
match the PAN ID of the test system