7 Run Power Calibration
S9101A 5G Multi-Band Vector Transceiver, Startup Guide
75
7. 4. 3. 2 Calibrating S9101A-BK1
Calibration 1 of 2: Power from RRH 1 RFHD 1 -> RRH 1 RFHD 2
This calibration is used to calibrate FR2 ports
(with
RF Tx/Rx 1
➀
used as the RF Output) on an
S9101A-BK1 5G Multi-Band Vector Transceiver TR1 with Blocker.
When performing this Power Calibration, the Source (Tx) output
power level is set to -5 dBm by default. The power level from
M9410A PXIe VXT #1 is calibrated while the RF Output for
M9410A PXIe VXT #2 is set to Off.
1. Calibrate the Source (Tx) signal path
a. Select the Power Calibration tab.
b. Select the Operation drop-down arrow and select
Calibration
.
c. Select the Calibration Step(s) drop-down arrow and select
Complete
.