Set the Output Current
Method 1
Use the left and right navigation keys to navigate to the setting that you wish to change.
In the display below, the current limit setting is selected. Use the up and down navigation keys to
toggle between the + and - limit entries. Enter a value using the numeric keypad. Then press Select.
You can also use the numeric arrow keys to adjust the value up or down. You can set both positive and
negative current values. Values become effective when the output is turned on.
In current priority mode, the unit will maintain the output current at its programmed setting. In voltage
priority mode, the unit will limit the output current when it reaches the specified current limit value.
Refer to
for more information.
Method 2
Use the Current key to select the current entry field. In the display below, the current setting is
selected. Enter the desired setting using the numeric keypad. Then press Enter.
If you make a mistake, either use the backspace key to delete the number, press Back to back out of
the menu, or press Meter to return to meter mode.
3 Getting Started
84
Keysight N69100 Series Operating and Service Guide
Содержание N69100 Series
Страница 1: ...Keysight Advanced Power System DC Power Supply N69100 Series Operating and Service Guide...
Страница 2: ......
Страница 14: ......
Страница 50: ...Outline Diagram for 10 kW Models 1 Quick Reference 50 Keysight N69100 Series Operating and Service Guide...
Страница 51: ...Outline Diagram for 20 kW Models Keysight N69100 Series Operating and Service Guide 51 1 Quick Reference...
Страница 52: ......
Страница 80: ......
Страница 94: ......
Страница 210: ...Status Diagram 5 SCPI Programming Reference 210 Keysight N69100 Series Operating and Service Guide...
Страница 212: ...Trigger Diagram 5 SCPI Programming Reference 212 Keysight N69100 Series Operating and Service Guide...
Страница 230: ...Models N69172A and N69173A 6 Verification and Calibration 230 Keysight N69100 Series Operating and Service Guide...
Страница 244: ......