![Keysight Technologies N69100 Series Скачать руководство пользователя страница 193](http://html1.mh-extra.com/html/keysight-technologies/n69100-series/n69100-series_operating-and-service-manual_1962218193.webp)
STATus:OPERation:ENABle <
value
>
STATus:OPERation:ENABle?
Sets the value of the
for the
group. The enable register is a mask for
enabling specific bits from the Operation Event register to set the OPER (operation summary) bit of the
Status Byte register. STATus:PRESet clears all bits in the enable register.
Parameter
Typical Return
A decimal value corresponding to the binary-
weighted sum of the register's bits.
<bit value>
Enable bit 3 and 4 in the enable register: STAT:OPER:ENAB 24
l
For example, with bit 3 (value 8) and bit 5 (value 32) set and enabled, the query r40.
l
*CLS does not clear the enable register, but does clear the
.
STATus:OPERation:NTRansition <
value
>
STATus:OPERation:NTRansition?
STATus:OPERation:PTRansition <
value
>
STATus:OPERation:PTRansition?
Sets and queries the value of the
(Negative-Transition) and
(Positive-Transition) registers.
These registers serve as a polarity filter between the Operation Condition and Operation Event
registers.
When a bit in the NTR register is set to 1, then a 1-to-0 transition of the corresponding bit in the
Operation Condition register causes that bit in the Operation Event register to be set.
When a bit in the PTR register is set to 1, then a 0-to-1 transition of the corresponding bit in the
Operation Condition register causes that bit in the Operation Event register to be set.
STATus:PRESet sets all bits in the PTR registers and clears all bits in the NTR registers.
Parameter
Typical Return
A decimal value corresponding to the binary-
weighted sum of the register's bits.
<bit value>
Enable bit 3 and 4 in the NTR register: STAT:OPER:NTR 24
Enable bit 3 and 4 in the PTR register: STAT:OPER:PTR 24
l
If the same bits in both NTR and PTR registers are set to 1, then any transition of that bit at the
Operation Condition register sets the corresponding bit in the Operation Event register.
l
If the same bits in both NTR and PTR registers are set to 0, then no transition of that bit at the Oper-
ation Condition register can set the corresponding bit in the Operation Event register.
l
The value returned is the binary-weighted sum of all enabled bits in the register.
Keysight N69100 Series Operating and Service Guide
193
5 SCPI Programming Reference
Содержание N69100 Series
Страница 1: ...Keysight Advanced Power System DC Power Supply N69100 Series Operating and Service Guide...
Страница 2: ......
Страница 14: ......
Страница 50: ...Outline Diagram for 10 kW Models 1 Quick Reference 50 Keysight N69100 Series Operating and Service Guide...
Страница 51: ...Outline Diagram for 20 kW Models Keysight N69100 Series Operating and Service Guide 51 1 Quick Reference...
Страница 52: ......
Страница 80: ......
Страница 94: ......
Страница 210: ...Status Diagram 5 SCPI Programming Reference 210 Keysight N69100 Series Operating and Service Guide...
Страница 212: ...Trigger Diagram 5 SCPI Programming Reference 212 Keysight N69100 Series Operating and Service Guide...
Страница 230: ...Models N69172A and N69173A 6 Verification and Calibration 230 Keysight N69100 Series Operating and Service Guide...
Страница 244: ......