![Keysight Technologies N69100 Series Скачать руководство пользователя страница 192](http://html1.mh-extra.com/html/keysight-technologies/n69100-series/n69100-series_operating-and-service-manual_1962218192.webp)
STATus Subsystem
Status register programming lets you determine the operating condition of the instrument at any time.
The instrument has three groups of status registers; Operation, Questionable, and Standard Event.
The Operation and Questionable status groups each consist of the Condition, Enable, and Event
registers as well as NTR and PTR filters.
The Status subsystem is also programmed using Common commands. Common commands control
additional status functions such as the Service Request Enable and the Status Byte registers. Refer to
for more information.
STATus:OPERation[:EVENt]
Queries the
for the
group. This is a read-only register, which stores
(latches) all events that are passed by the Operation NTR and/or PTR filter. Reading the Operation
Status Event register clears it.
Parameter
Typical Return
(none)
<bit value>
Read the operation status event register: STAT:OPER?
l
The value returned is the binary-weighted sum of all enabled bits in the register. For example,
with bit 3 (value 8) and bit 5 (value 32) set and enabled, the query r40.
l
*RST has no effect on this register.
STATus:OPERation:CONDition?
Queries the
for the
group. This is a read-only register, which holds
the live (unlatched) operational status of the instrument. Reading the Operation Status Condition
register does not clear it.
Parameter
Typical Return
(none)
<bit value>
Read the operation status condition register: STAT:OPER:COND?
l
The value returned is the binary-weighted sum of all enabled bits in the register. For example,
with bit 3 (value 8) and bit 5 (value 32) set and enabled, the query r40.
l
The condition register bits reflect the current condition. If a condition goes away, the cor-
responding bit is cleared.
l
*RST clears this register, other than those bits where the condition still exists after *RST.
5 SCPI Programming Reference
192
Keysight N69100 Series Operating and Service Guide
Содержание N69100 Series
Страница 1: ...Keysight Advanced Power System DC Power Supply N69100 Series Operating and Service Guide...
Страница 2: ......
Страница 14: ......
Страница 50: ...Outline Diagram for 10 kW Models 1 Quick Reference 50 Keysight N69100 Series Operating and Service Guide...
Страница 51: ...Outline Diagram for 20 kW Models Keysight N69100 Series Operating and Service Guide 51 1 Quick Reference...
Страница 52: ......
Страница 80: ......
Страница 94: ......
Страница 210: ...Status Diagram 5 SCPI Programming Reference 210 Keysight N69100 Series Operating and Service Guide...
Страница 212: ...Trigger Diagram 5 SCPI Programming Reference 212 Keysight N69100 Series Operating and Service Guide...
Страница 230: ...Models N69172A and N69173A 6 Verification and Calibration 230 Keysight N69100 Series Operating and Service Guide...
Страница 244: ......