![Keysight Technologies N69100 Series Скачать руководство пользователя страница 153](http://html1.mh-extra.com/html/keysight-technologies/n69100-series/n69100-series_operating-and-service-manual_1962218153.webp)
ABORt Subsystem
Abort commands cancel any active transients and return the trigger system back to the Idle state.
Abort commands are also executed with the *RST command.
ABORt:ACQuire
ABORt:TRANsient
ABORt:ACQuire - Cancels any triggered measurements. It also resets the WTG-meas and MEAS-
active bits in the Operation Status registers.
ABORt:TRAN - Cancels any transients or Arbs. It also resets the WTG-tran and TRAN-active bits in the
Operation Status registers. Note that this command does not turn off continuous triggers if
INITiate:CONTinuous:TRANsient ON has been programmed. In this case, first turn off continuous
triggers before sending the ABORt command.
Parameter
Typical Return
(none)
(none)
Aborts the triggered measurement: ABOR:ACQ
Keysight N69100 Series Operating and Service Guide
153
5 SCPI Programming Reference
Содержание N69100 Series
Страница 1: ...Keysight Advanced Power System DC Power Supply N69100 Series Operating and Service Guide...
Страница 2: ......
Страница 14: ......
Страница 50: ...Outline Diagram for 10 kW Models 1 Quick Reference 50 Keysight N69100 Series Operating and Service Guide...
Страница 51: ...Outline Diagram for 20 kW Models Keysight N69100 Series Operating and Service Guide 51 1 Quick Reference...
Страница 52: ......
Страница 80: ......
Страница 94: ......
Страница 210: ...Status Diagram 5 SCPI Programming Reference 210 Keysight N69100 Series Operating and Service Guide...
Страница 212: ...Trigger Diagram 5 SCPI Programming Reference 212 Keysight N69100 Series Operating and Service Guide...
Страница 230: ...Models N69172A and N69173A 6 Verification and Calibration 230 Keysight N69100 Series Operating and Service Guide...
Страница 244: ......