![Keysight Technologies N6900 Series Скачать руководство пользователя страница 283](http://html1.mh-extra.com/html/keysight-technologies/n6900-series/n6900-series_operating-and-service-manual_1962217283.webp)
Parameter
Typical Return
0 to 6.4
Ω
(model dependent)|MIN|MAX, *RST 0
0
Specifies an output resistance of 0.5 ohms: VOLT:RES 0.5
[SOURce:]VOLTage:RESistance:STATe 0|OFF|1|ON
[SOURce:]VOLTage:RESistance:STATe?
Enables or disables output resistance programming in voltage priority mode.
Parameter
Typical Return
0|OFF|1|ON, *RST OFF
0 or 1
Turns resistance programming on: VOLT:RES:STAT ON
[SOURce:]VOLTage:SLEW[:IMMediate] <
value
>|MIN|MAX|INFinity
[SOURce:]VOLTage:SLEW[:IMMediate]? [MIN|MAX]
Sets the voltage slew rate. The slew rate is set in volts per second and affects all programmed
voltage changes, including those due to the output state turning on or off. The slew rate can be set to
any value between 0 and 9.9E+37. For very large values, the slew rate will be limited by the analog
performance of the output circuit. The keywords MAX or INFinity set the slew rate to maximum.
Parameter
Typical Return
0 – 9.9E+37, *RST MAX
<max value>
Sets the output slew rate to 5 V per second: VOLT:SLEW 5
l
The query returns the value that was sent, unless the value is less than the minimum slew rate, in
which case the minimum value is returned. The resolution of the slew setting is also the minimum
value, which can be queried using VOLTage:SLEW? MIN. The exact value varies slightly according
to calibration.
[SOURce:]VOLTage:SLEW:MAXimum 0|OFF|1|ON
[SOURce:]VOLTage:SLEW:MAXimum?
Enables or disables the maximum slew rate override. When enabled, the slew rate is set to its
maximum value. When disabled, the slew rate is set to the immediate value set by the
[SOURce:]VOLTage:SLEW command. Use [SOURce:]VOLTage:SLEW? MAX to query the maximum
slew rate that was set.
Parameter
Typical Return
0|OFF|1|ON, *RST ON
0 or 1
Enable the maximum slew rate override: VOLT:SLEW:MAX ON
6 SCPI Programming Reference
283
Keysight N6900/N7900 Series Operating and Service Guide
Содержание N6900 Series
Страница 1: ...Keysight Advanced Power System N6900 N7900 Series Operating and Service Guide...
Страница 2: ......
Страница 63: ...1 kW Models Keysight N6900 N7900 Series Operating and Service Guide 63 1 Quick Reference...
Страница 64: ...2 kW Models 1 Quick Reference 64 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 78: ...2 Installing the Instrument 78 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 90: ...Rack Mounting 2 Installing the Instrument 90 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 289: ...Status Diagram 6 SCPI Programming Reference 289 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 354: ...Cover screws 8 Service and Maintenance 354 Keysight N6900 N7900 Series Operating and Service Guide...